112
ML-3030AS/3015AS
2 . Control Panel Functions
2 . Control Panel Functions
This section explains the functions of the control panel .
At PANEL CONTROL, welding schedules are set by using the control panel keys and
laser light is output by pressing the LASER START/STOP button. After the output,
you can check the laser output energy on the MONITOR screen.
⇒
When the optional laser controller is connected, laser welding operations can be
performed by using the control panel of the laser controller in the same way in a
place remote from the laser.
When the laser controller is used, the control panel and LASER START/STOP
button of the main unit cannot be used. However, the EMERGENCY STOP but-
ton and CONTROL keyswitch can be used.
Function of Each Section on the Control Panel
(1)
EMERGENCY
STOP Button
This is an emergency stop button. With this button pressed, the laser
welder operation is stopped and the same state as that provided by turn-
ing OFF the CONTROL keyswitch is provided. When the pressed button
is turned in the direction of RESET (clockwise), the button is reset to the
initial state.
(2) LASER
START/STOP
(Button)
EMISSION
(Lamp)
If you press the button when a laser light output becomes ready, laser
light is output. If the button is pressed again while laser light is repeat-
edly output, the repeated output is stopped.
*
Pin No.25 (control switching) of the EXT. I/O (1) connector is in a
closed circuit and the LD is turned on.
When the LD is turned on, the EMISSION lamp comes on.
(3)
Control Panel
This panel is used to set welding schedules and operate the laser.
Setting items and set values are displayed on the liquid crystal display.
(1)
(3)
(2)
Summary of Contents for ML-3015AS