100
ML-3030AS/3015AS
4 . Setting the Laser Light Output Schedule
Limitations of Schedule Setting
Set schedules so as to satisfy following ranges.
FIX/FLEX
CW
ML-3030AS
ML-3015AS
ML-3030AS
ML-3015AS
PEAK POWER
0.5 to 2.7 kW
0.25 to 1.35 kW
50 to 270 W
25 to 135 W
REPEAT
1 to 1000 pps
―
SHOT
1 to 9999 (9999 is for endless output.)
―
TIME
0.1ms resolution: 0 to 50.0 ms
0.01ms resolution: 0, 0.05 to 50.00 ms
(Can be set in 0.05ms steps. In FIX,
set a lower value than FLASH for
SLOPE.)
1s resolution: 0 to 9999 sec
0.1s resolution: 0.0 to 999.9 sec
0.01s resolution: 0.00 to 99.99 sec
0.001s resolution: 0.000 to 9.999 sec
POWER
0 to 200.0%
Modulation setting, FREQUENCY
1 to 5000 Hz
Modulation setting, MODULATION
0 to 100%
Modulation setting, DUTY
10 to 90%
SEAM setting, COUNT
0 to 9999
(Higher value than the previous
POINT. POINT 01 is 1.)
―
SEAM setting, POWER
0 to 150.0%
―
Laser output value *1, *2
0.0 to 2.7 kW
0.00 to 1.35 kW
0 to 270 W
0 to 135 W
(However, when the value is lower
than a lower limit, the actual output
becomes a lower limit. *3)
(However, when the value is lower
than a lower limit, the actual output
becomes a lower limit.)
Total output time
(FIX: sum of FLASH1 to 3 and COOL1
to 2 TIMEs)
(FLEX/CW: sum of all TIMEs)
0.1ms resolution: 0, 0.2 to 50.0 ms
0.01ms resolution: 0, 0.20 to 50.00 ms
(Can be set in 0.05 ms steps)
1s resolution: 0 to 10000 sec
0.1s resolution: 0.0 to 1000.0 sec
0.01s resolution: 0.00 to 100.00 sec
0.001s resolution: 0.000 to 10.000 sec
REPEAT setting in pulse waveform
Total output time (sec) > 1 / (REPEAT ×
2)
―
Output energy (REFERENCE VALUE)
0 to 30 J
0 to 15 J
―
Average output
(output energy × REPEAT)
300 W
150 W
―
*1 The laser output value is as follows:
PEAK POWER × (POWER + modulation setting MODULATION / 2) × SEAM setting
maximum POWER / 100
(Calculated supposing that the MODULATION is 0 when modulation setting is OFF,
or the SEAM setting maximum POWER is 0 when the SEAM setting is OFF.)
When the above expression is not satisfied, the following dialogue appears and the
schedule setting can not be changed. Review the settings of parameters displayed on
the dialogue.
Summary of Contents for ML-3015AS
Page 21: ...Introduction Part...
Page 22: ......
Page 30: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 52: ......
Page 53: ...Operating Part...
Page 54: ......
Page 163: ...Maintenance Part...
Page 164: ......
Page 175: ...Appendixes...
Page 176: ......