94
MF-C300A-SF/C500A-SF
4 . Setting the Laser Light Output Schedule
MODULATION
Outputs the waveform added/subtracted half of the modulation width to/from
the set laser waveform.
Sets the modulation width in the range of 0 to 100% supposing that the set
SET POWER is 100%.
<Note>
Set the modulation width so that the waveform after modulation becomes in
the range between the minimum of the laser output and the maximum.
FREQUENCY
Sets the frequency of the laser output value.
The setting range is 1 to 5000 Hz. Sets the cycle of modulation.
MODU
Set the modulation function to ON or OFF.
When this item is set to ON, the settings is enabled. When the item is set to
OFF, this function is disabled.
<Note>
When using the modulation function, set the laser output value (POWER [%])
to 100%.
WAVE
Sets the type of modulation waveform from rectangular wave (RECT), trian-
gular wave (TRI), or sinusoidal wave (SINE).
X
Returns to the SCHEDULE screen.
⇒
For the common items in the upper/lower part of the screen, refer to page 57.