82
MF-C300A-SF/C500A-SF
4 . Setting the Laser Light Output Schedule
Fn
When this button is pressed, a window to select function is displayed and the fol-
lowing editorial assistant functions can be used.
RESET: Initializes the currently-selected schedule.
COPY:
Copies the currently-selected schedule to a temporary memory buffer.
PASTE:
Restores data from a temporary memory buffer to the currently-select
-
ed schedule.
⇒
For the common items in the upper/lower part of the screen, refer to page 57.
<Notes>
- The laser output value (%) setting range is 0 to 200% . However, the laser output
value cannot be set exceeding the maximum value of “SET POWER” x 100% . If the
laser output value is set to 100%, the value set in “SET POWER” is selected .
- There are limitations of the total time of the laser output time COOL1 +
COOL2 + FLASH3 in combination with values of SET POWER and RE-
PEAT . For details, refer to “Limitations of Schedule Setting” on page 99 .
- Within the range of 10% of the maximum SET POWER, a constant power is output
to protect the laser oscillator without reference to waveform input . For details,
refer to “Limitations of Schedule Setting” on page 99 .
Preliminary Oscillation
To stabilize the laser oscillation, the minimum power of laser (15 W (MF-C300A-SF)
or 25 W (MF-C500A-SF)) is output for 0.5 ms immediately before laser output. The
preliminary oscillation is performed during the non-laser output time, but when the in-
terval of time between laser outputs is shorter than 0.8 ms, the preliminary oscillation
cannot be performed and the minimum power of laser is output during the set time.
The non-laser output time is any of the following:
• Laser output time (ms) whose laser output value (%) is set to 0%
• Set time of COOL1/COOL2
• Time interval between laser outputs set for REPEAT (*)
*: When the interval of time between laser outputs is shorter than 0.8 ms, the mini-
mum power of laser is also output during other non-laser output times.
Non-laser output time 0 .8 ms or longer Shorter than 0 .8 ms
100%
Minimum power
Summary of Contents for MF-C300A-SF
Page 20: ......
Page 21: ...Introduction Part...
Page 22: ......
Page 36: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 42: ......
Page 50: ......
Page 51: ...Operating Part...
Page 52: ......
Page 114: ......
Page 159: ...Maintenance Part...
Page 160: ......
Page 176: ......
Page 177: ...Appendixes...
Page 178: ......