54
MF-C2000A Series
3 . Connecting the Hose for Cooling Water
3 . Connecting the Hose for Cooling Water
This section explains how to connect the hose for cooling water to the cooling
water inlet and the cooling water outlet .
Item required
Braided hose (Inner diameter: φ 15 mm), hose clip, slotted screwdriver, tube (φ 8 and
φ 6) (attached to the chiller), coupling (attached to the chiller), and spanner (14 mm)
Operating Procedure
(1) Connect the attached braided hoses to the cooling water inlet and the cooling
water outlet on the rear surface of the main unit, and fix them with
hose clips.
Connect each end of the hoses to the water discharge port and the water outlet
and inlet of the chiller.
⇒
Be careful about INLET and OUTLET.
(2) Connect the attached
φ 8 tubes to the chiller connector, and fix them with
hose
clips.
(3) Connect the
φ 8 tubes connected to the chiller to the pipes of the fiber connector
after being relayed by the φ 6 tubes with couplings
.
⇒
It is recommended that the length of the φ 6 tube be 100 mm or shorter on each
side of IN/OUT. When the length is longer than 100 mm, the pressure loss be-
comes greater and a flow rate error may occur.
⇒
Refer to the Appendixes, “Dimensional Outline Drawings” for the shape of the fi
-
ber connector.
⇒
Refer to the next page for how to connect the coupling.
φ8 tube
(10 m max .)
φ6 tube
Coupling
Braided hose
(5 m max .)
Main unit
Chiller
Fiber connector
Summary of Contents for MF-C2000A Series
Page 1: ...AA04OM1209213 07 FIBER LASER WELDER MF C2000A Series OPERATION MANUAL ...
Page 21: ...Introduction Part ...
Page 22: ......
Page 34: ......
Page 42: ......
Page 43: ...Installation and Preparation Part ...
Page 44: ......
Page 73: ...Operating Part ...
Page 74: ......
Page 78: ......
Page 142: ......
Page 212: ......
Page 213: ...Maintenance Part ...
Page 214: ......
Page 232: ......
Page 244: ......
Page 245: ...Appendixes ...
Page 246: ......