Precautions for Handling
11
MF-C2000A Series
⇒
To prevent damage, do not bend the optical fiber beyond its
minimum bending
radius or apply any forms of shock to it (See table below).
Bending radius
Min. 150 mm
Coil radius
Min. 200 mm
Tensile force
Max. 50 N
Torque (torsion)
Max. 0.5 Nm
Torsion
Max. 90° per meter
⇒
When a supervisor or operator enters the area where the laser is used, protective
measures not to exceed the MPE* level must be taken.
* MPE: The maximum level of permissible exposure of the eyes or skin to laser beams. Abbreviation of
Maximum Permissible Exposure.
* For other information on managing laser equipment or the MPE level, refer to the
following standards.
Japanese Industrial Standards JIS C 6802 “Safety of Laser Products”
Notification by the Ministry of Health, Labor and Welfare No. 0325002 “Laser Dam
-
age Prevention Measures”