10.1.7 Checking the oil level in the centre gearbox
INTERVAL
After initial operation
Every 50 operating hours
or
weekly
ENVIRONMENTAL INFORMATION
Danger due to escaping oil
Collect any escaping oil.
Dispose of cleaning agents for removing
oil in an environmentally friendly manner.
1.
Park the implement on a horizontal surface.
2.
Remove the ventilation
1
.
3.
Remove the bolt
2
.
NOTE
If oil types are mixed, warranty claims cannot be
accepted.
Do not mix oils.
Fill with new and clean gear oil.
4.
Refill oil through the ventilation opening.
When oil emerges from the thread of the bolt, the
correct oil level has been reached.
5.
Install the bolt.
6.
Install the ventilation.
2
1
CMS-I-00006847
CMS-T-00010086-A.1
10 | Repairing the machine
Maintaining the machine
MG7512-EN-GB | C.1 | 29.09.2022 | © AMAZONE