![Alvarion BreezeMAX PRO-S CPE Product Manual Download Page 81](http://html1.mh-extra.com/html/alvarion/breezemax-pro-s-cpe/breezemax-pro-s-cpe_product-manual_2915112081.webp)
Configuring Basic Parameters
BreezeMAX CPEs Product Manual
59
3.2
Configuring Basic Parameters
3.2.1
The Basic Parameters
Table 3-1: SU's Basic Parameters
Parameter
Default Value
Comment
Ethernet Port auto Negotiation
Enable/Disable
Enabled
Applicable only to E-model units (with Ethernet
interface).
Ethernet Port Speed and Duplex
Applicable only to E-model units (with Ethernet
interface). Applicable only if Ethernet Port Auto
Negotiation Enable/Disable is set to Disable
User Name
Null, changed
automatically to MAC
address if not configured
to any other value
Should be supplied by system administrator
User Password
quickynikynyoky
Should be supplied by system administrator
Organization Name
Optional - according to administrator policy
Address
Optional- according to administrator policy
Country
Optional- according to administrator policy
BST/AU ID
186.190.0.0.250.206
BST/AU ID ID Mask
0.0.0.0.0.0
Preferred BST/AU ID
186.190.0.0.250.206
Preferred BST/AU ID Mask
0.0.0.0.0.0
Set Mobility Mode
nomadic
Bandwidth
3.5 MHz
Antenna (Si CPE only)
Automatic
Scanning Start Frequency
Depend on Radio Band
and Bandwidth
Scanning End Frequency
Depend on Radio Band
and Bandwidth
Scanning Main Step
875 KHz
Scanning Intermediate Steps
Enable for all eight Steps
Discrete Frequencies
None
Rx Attenuator (2.3 GHz units
only)
0