Chapter 3 - Commissioning
Configuring Basic Parameters
BreezeMAX PRO 5000 CPE
33
Product Manual
3.2.2
Configuration Tools
The CPEs include a Web Configuration Server, providing a web-based GUI for
local configuration and monitoring. The Web Configuration Server can be
accessed using a PC/Notebook with a web browser.
The CPE may be delivered with the operator’s default settings already configured
in the FLASH memory. The only parameters that should be configured (if
necessary) are the end user’s credentials (User Name and User Password).
3.2.3
Using the Web Configuration Server
1
Connect a PC/Notebook with a web browser to the Ethernet port of the CPE,
using a straight Ethernet cable.
2
Configure the PC's IP parameters to enable connectivity with the unit. The IP
address of the CPE for local management access is 192.168.254.251. The
Subnet Mask is 255.255.255.0. The recommended IP address for the PC is
192.168.254.250, as this is also the default TFTP Sever IP Address (required
for downloading SW versions and for downloading/uploading configuration
files).
3
Open a web browser, and connect to http://192.168.254.251. The “Enter the
Password” prompt is displayed. Enter the password and press the Enter key.
NOTE
Most parameters are changed to their new values only after reset (refer to
details). Once the basic parameters are configured, the unit should be reset in order to activate the
new configuration.
To configure basic parameters:
NOTE
The default password is "installer".
Summary of Contents for BreezeMAX PRO 5000 CPE
Page 1: ...BreezeMAX PRO 5000 CPE Product Manual Software Version 1 5 April 2010 P N 215643...
Page 17: ...Tables BreezeMAX PRO 5000 CPE xvii Product Manual Table 4 3 CPE Parameters Summary 85...
Page 18: ...1 Chapter Product Description...
Page 27: ...2 Chapter Installation...
Page 46: ...3 Chapter Commissioning...
Page 58: ...4 Chapter Operation...
Page 105: ...A Appendix Troubleshooting...
Page 109: ...Glossary...