48
BreezeMAX Wi² and BreezeACCESS Wi² System Manual
Chapter 3 - Hardware Installation Wi² Extender
The color codes used in standard cables supplied by Alvarion are as listed in the following table:
3.4.3
Grounding Wire
Be sure to ground the Outdoor Unit with an appropriate grounding wire (not included) by
connecting the grounding point on the base of the unit to a good ground (earth) connection.
Figure 3-2: Ethernet Connector Pin Assignments
Table 3-2: Cable Color Codes
Wire color
Pin
Blue 1
Blue/white
2
Orange
3
Orange/white
6
Brown
4
Brown/white
5
Green
7
Green/white 8
CAUTION
Be sure that grounding is available and that it meets local and national electrical codes. For
additional lightning protection, use lightning rods, lightning arrestors, or surge suppressors.