BreezeMAX Wi² and BreezeACCESS Wi² System Manual
Chapter 2 - Hardware Installation
2.3.4
Preparing the Power Cable
1
Use a UL/CSA listed smooth circular power cable, 1.5mm to 2.5mm each. Outer diameter 7mm
to 9mm, UV resistant, temperature range -40°C to + 65°C (-40°F to +149°F) minimum. Other
specifications (such as oil resistance, no of wires) according to specific installation
requirements.
2
Use a cap assembly tool to unscrew the locking ring.
3
Thread the cable through component parts as shown in
.
CAUTION
Electric Shock Hazard. Only a licensed electrician should connect the power plug.
All mains used outdoors, in damp or wet conditions, should be supplied from a correctly fused
source and protected according to applicable local regulations.
To prepare the power cable:
NOTE
shows an AC power jack. The DC power jack is similar, but has only two sockets.