Minimum Pulses to Detect
- The Minimum Pulses to Detect parameter defines
the minimum number of radar pulses that should be detected before reaching a
decision that radar is active on the channel.
The range is from 1 to 100 pulses.
The default is 4 pulses
DFS Detection Algorithm
- The DFS Detection Algorithm option is applicable
only to units using a Universal Country Code in either the 5.4 GHz or the 5.8 GHz
band (Country Codes 1060 and 1064), enabling to select the DFS detection
algorithm if DFS should be enabled.
The available options are ETSI and FCC.
The default is ETSI.
Bandwidth (MHz)
– Sets the channel bandwidth:
10
- 10 MHz channels
20
- 20 MHz channels
10-20
- Either 10 or 20 MHz channels
The default value is 10-20.
Select All
– Selects all available frequencies in the regulatory domain.
Clear All
– De-selects all available frequencies in the regulatory domain (at least
one frequency will be retained for security purposes).
LED Operation Mode
– Allows users to customize the operation mode for the 7
SNR leds. The leds are numbered as follows: from 1 to 3 the first 3 LEDs from left
to right on the upper row, and from 4 to 7 the LEDs on the second row from left to
right. The Power LED’s behavior is not affected by these settings:
Normal
- This is the default mode of operation where the LEDs indicate the
Threshold
- Allows customization for each LED behavior by setting a
Modulation, SNR, CRC or RSSI threshold in respect to which the LED will light
Summary of Contents for BreezeACCESS SU-A-EZ
Page 1: ...Product Manual Software Version 3 1 December 2009 P N 215448 BreezeACCESS SU A EZ ...
Page 17: ...Table of Contents BreezeACCESS SU A EZ xvii Product Manual ...
Page 18: ...1 Chapter Product Description ...
Page 26: ...2 Chapter Hardware Installation ...
Page 48: ...3 Chapter Initial Configuration ...
Page 56: ...4 Chapter Web managed Configuration ...
Page 88: ...5 Chapter Command Line Interface ...
Page 156: ...A Appendix Troubleshooting ...
Page 159: ...B Appendix Using the Set Factory Defaults Utility ...
Page 162: ...Glossary ...