Chapter 5 - Command Line Interface
Regulatory Domain Commands
BreezeACCESS SU-A-EZ
86
Product Manual
5.5.3
dynamicfreq
This command allows you to set one or more individual frequencies and a range of
frequencies, allowed by the chosen regulatory domain.
Syntax
dynamicfreq
<
f1,f2,f3-f4
>
•
f1,f2,f3-f4
- Specify the individual frequencies and/or frequency ranges that you wish
to replace the already configured scanning frequency list, in MHz, separated by comas
and no spaces. For a frequency range, separate the beginning and ending frequencies
with a “-”, i.e. for the frequencies 5.26GHz, 5.54GHz, and the range 5.7~5.785 type
‘5260,5540,5700-5785’
Default Setting
None
Command Mode
Installer, Admin
Example
In this example the frequencies 5.260GHz, 5.540GHz, and 5.700GHz to 5.785GHz
are added within the band allowed by the chosen regulatory domain FCC. The
getfreq command is then used to display all selected frequencies.
Installer# dynamicfreq 5260,5540,5700-5785
...
Installer# getfreq
...
5260,5540,5700,5745,5765,5785