Installation Instructions [email protected] +1(909) 591-8431 www.alvaradomfg.com
Page 37
Appendix C - FMST Installation
1.
Determine where the turnstile will be installed. Consider
the overall footprint size of the unit when determining
the installation location (Figure C1). Once the installation
location has been determined, use a chalk line to mark
the centerline of the turnstile.
Default entry rotation is counterclockwise. Confirm correct
entry direction prior to installation.
2. Reconfirm the centerline location for the yoke
(Figure C2).
3. Continue installation as shown in the "Yoke
Installation" section.
Fig. C1
Fig. C2
Bottom Bearing
Plate Center
CL
FMST Illustrated Parts List
Yoke
(Qty 1)
Roto
(Qty 1)
OV
(Qty 1)
Entry Side
(Unsecured)
Exit Side
(Secured)
CL
62.00"
(1575mm)
30.0"
(762mm)
30.5"
(775mm)
29.63"
(752mm)
These instructions are for installing the yoke section of the FMST. When complete, please refer back to the "OV
Installation" section.
FMST Installation Instructions
NOTES
The overall height of the FMST is 91.5". However, an
additional 3" of clearance must be added for service and
maintenance.