* After approximately 4 seconds, voltage will drop to approximately 2.7VDC connected to the load of the solenoid.
Terminal Descriptions
BOARD NAME
DESCRIPTION
RATING
EXPLANATION
J18
CCW
Solenoid VDC wire connection - Counter
Clockwise Direction
12 -
15.73VDC*,
1.53A
Connection for Counter Clockwise Solenoid. Universal
polarity.
J18
CCW
Solenoid VDC wire connection - Counter
Clockwise Direction
12 -
15.73VDC*,
1.53A
Connection for Counter Clockwise Solenoid. Universal
polarity.
J18
CW
Solenoid VDC wire connection -
Clockwise Direction
12 -
15.73VDC*,
1.53A
Connection for Clockwise Solenoid. Universal polarity.
J18
CW
Solenoid VDC wire connection -
Clockwise Direction
12 -
15.73VDC*,
1.53A
Connection for Clockwise Solenoid. Universal polarity.
SW7
CCW
Entry
Activation
Test
Button
Allows user to test turnstile activation -
Counter Clockwise Direction
N/A
Depressing button simulates input to J3 ACC, “Entry
Accept”. If turnstile solenoid “fires” after depressing
button AND re-locks after a single rotation of the Roto or
upon time out, the turnstile is functioning correctly in the
Left Hand/Counter Clockwise Direction.
J3
ACC
Entry
Accept
“Card Authorized” input connection from
the access control system - Counter
Clockwise Direction
0VDC,
18mA
This connection is used to tell the turnstile to unlock.
The ATC will accept a N.O. dry contact signal of .5
seconds to 2 seconds from the access control system
and allow one rotation of the Roto before re-locking.
J3
GND
Ground
Ground wire connection from the access
control system - Counter Clockwise
Direction
0VDC,
18mA
Ground wire connection position for ACC and REJ
contact signal.
J3
REJ
Entry
Reject
“Card Reject” input connection from
the access control system - Counter
Clockwise Direction
0VDC,
18mA
This connection is used to tell the turnstile to remain
locked. The access control system has determined that
the card presented is unauthorized for entry.
J3
CLS
Close
Passage
Connection for placing turnstile in locked
“CLOSED” status - Counter Clockwise
Direction
0VDC,
18mA
Providing a continuous dry contact at this terminal places
the turnstile in a locked “CLOSED” mode. This mode
overrides the access control system operation. If status
lights are installed (Location J19) the red light will be
illuminated continuously.
J3
GND
Ground
Ground wire connection for “OPN/CLS”
lane control - Counter Clockwise Direction
0VDC,
18mA
Ground wire connection for “OPN/CLS” passage control.
J3
OPN
Open
Passage
Connection for Fire Alarm System, or
placing turnstile in “OPEN” status -
Counter Clockwise Direction.
0VDC,
18mA
Providing a continuous dry contact at this terminal places
the turnstile in an “OPEN” mode. Typically, this terminal
is used to connect the fire alarm system (normally open
type) when the turnstile is configured for counterclockwise
rotation in the exit direction.
J3
CNT
Passage
Count
Confirmation signal upon turnstile rotation
- Counter Clockwise Direction
0VDC,
18mA
Outputs a dry contact upon rotation of the turnstile.
This feature can be used to output a “count” signal to
an external system such as Alvarado’s GateWatch or
to provide feedback to the access control system that a
turnstile rotation has taken place.
J3
COM
Passage
Count
Confirmation signal upon turnstile rotation -
Counter Clockwise Direction
0VDC,
18mA
Common dry contact connection for CNT count signal
output. See J3 CNT description.
J10
X5RGY-
CCW
Connection for Activation Lights -
Counter Clockwise Direction
5VDC,
50mA
Connection for JS2 and JS3 activation lights.
J9
X5RGY-
CW
Connection for Activation Lights -
Clockwise Direction
5VDC,
50mA
Connection for JS2 and JS3 activation lights.
J7
ACC
Entry
Accept
“Card Authorized” input connection from
the access control system - Clockwise
Direction
0VDC,
18mA
This connection is used to tell the turnstile to unlock. The
ATC will accept a N.O. dry contact signal of .5 seconds to
2 seconds from the access control system and allow one
rotation of the Roto before re-locking.
J7
GND
Ground
Ground wire connection from the access
control system - Counter Clockwise
Direction
0VDC,
18mA
Ground wire connection position for ACC and REJ
contact signal.
J7
REJ
Entry
Reject
“Card Reject” input connection from
the access control system - Counter
Clockwise Direction
0VDC,
18mA
This connection is used to tell the turnstile to remain
locked.
The access control system has determined that the card
presented is unauthorized for entry.