CONNECTION AND OPERATIONAL MANUAL. CONTROL UNIT CUL01
4
4
ITEM DESCRIPTION
The company does not control item installation and automation devices, their service and opera-
tion, and therefore it is not responsible for installation, operation and technical service safety.
The recommendations written above should serve as an example because system installation
locations can be different. The installer is responsible for making the most appropriate decision.
The installer is responsible for work on the whole system. He must follow the existing norms and
standards (e.g., DIN 1986, EN 12050, EN 1398) in his work. He is also responsible for management
of technical documents which are delivered together with equipment.
The contents of this manual cannot be used as grounds for legal challenges.
2.
ITEM DESCRIPTION
The control unit is used for SL dock leveller with swing lip with 1-valve hydraulic unit. There is
a line circuit breaker
1
and control button
2
on the cover of the control unit body (
pic
. 1). The
dimensions for mounting are also shown on
pic
. 1 in millimetres.
1
2
190
28
0
25
4
180
Pic. 1.
CUL01
control unit
3.
SPECIfICATIONS
The following specifications are true if the ambient temperature is 20 (± 5) º С.
Table
1. Specifications
Parameters
Nominal values
Power supply voltage
3 ~ / 400 V or 230 V
Network frequency, Hz
50
Electric motor capacity, kW
< 1.2
Power consumption in stand-by mode, W
< 5
Operating supply voltage, W
24 DC
Wires connected to the sockets cross section, mm
2
max 2.5
Ingress protection rating
IP54 (professional installation)
Operating temperatures range, º С
− 25…+ 40
Power cord length / wire cross section
not less than 1 m / 1.5 m
2