OPERATING MANUAL FOR UNDER PLASTER SWITCH WITH RADIO RECEIVER DC 318

2. ILLUSTRATIVE SWITCH CONNECTION

Power supply: 

Operating temperature:

Works exclusively with motors without built-in radio control.
Works with all DC series transmitters included in the ALUPROF S.A. offer.
Possibility to program up to 20 transmitters, Each next transmitter will erase the first one.

230 VAC / 50 Hz

~ -10°C - ~ +55°C

Average range:

200 meters (in open space), 35 meters (inside buildings)

Frequency:

433.92 MHz

Company reserves the tolerance of catalog data due the different conditions usage.

In accordance with the provisions of the Directive of the European Parliament and of the Council 2012/19 / EU of 4 July 2012 
on waste electrical and electronic equipment (WEEE), it is prohibited to place of used equipment together with other wastes, 
marked with crossed out wheeled bin symbol. The users are obliged to transfer their used equipment to a designated collection 
point for proper processing. The marking means, at the same time, that the equipment was put on the market after 13 August 
2005. These legal obligations have been introduced to reduce the amount of waste generated from waste electrical and 
electronic equipment and to ensure an appropriate level of collection, recovery and recycling. The equipment does not contain 
any dangerous components, which would have any particularly negative impact on the environment and human health.

Applied for max 50 Nm tubular motor

230V / 50Hz

- Installation of the switch should be carried out by authorized persons (e.g. ECS authorisations to operate electrical devices up to 1 kV).

- The switch is designed for use in dry rooms and should not be exposed to direct weather conditions.

- The switch should be powered by a separate circuit and protected by a quick fuse for example: circuit breaker type B10.

NOTE

OPERATING MANUAL FOR UNDER PLASTER SWITCH WITH RADIO RECEIVER DC 318

1.  TECHNICAL SPECIFICATIONS

Failure to comply with this Manual may result in injury or death. 

Keep the Manual for reference.

80 x 80 (mm)

Dimensions: 

Radiated power:

10 miliwat (mW)

Summary of Contents for DC 318

Page 1: ...d equipment to a designated collection point for proper processing The marking means at the same time that the equipment was put on the market after 13 August 2005 These legal obligations have been introduced to reduce the amount of waste generated from waste electrical and electronic equipment and to ensure an appropriate level of collection recovery and recycling The equipment does not contain a...

Page 2: ...ons K1 first channel buttons MODE button activates the settings of the clock and date Activation of the P2 button in remote controller DC1670 DC1671 DC315 DC2291 is performed by a combination of both keys STOP and UP DC 305 DC 306 DC 313 DC 920 P2 P2 K UP STOP K DOWN UP STOP DOWN MODE P2 OK MODE P2 OK UP STOP DOWN P2 UP STOP DOWN UP STOP DOWN UP STOP DOWN K1 K2 UP STOP DOWN MODE K K K P2 K UP STOP...

Page 3: ...nsmitter Indicator light flashes 3 times The transmitter has been added Press and hold simultaneously UP and DOWN buttons with power supply on The indicator light is on 5 ERASING ONE TRANSMITTER Press and hold simultaneously UP and DOWN buttons with power supply on The indicator light is on After 3 seconds when the indicator light turns off release the Press STOP button The indicator light turns o...

Page 4: ...ep control of venetian blind 6 CHANGING THE OPERATING MODE PULSED CONTINUOUS 7 RESTORE FACTORY SETTINGS Press and hold simultaneously STOP and DOWN buttons with power supply on The indicator light is on After 6 seconds indicator light flashes 3 times Factory settings restored Headquarters Production plant in Bielsko Biała Production Plant in Opole Warszawska 153 43 300 Bielsko Biała Poland ul Gosł...

Reviews: