• Selectable wireless panel compatibility
• Rechargeable backup battery
• Automatic zone polarity and end of line detection
• Battery backed 12VDC output for powered zones
• Cover tamper
•
Certified to UL1023, ULC1023, UL1610, and ULC S304
PANEL ENROLLMENT
(For full zone enrollment instructions, refer to Advanced Setup, step 3
)
A
Enroll Translator into Panel.
• Trip the translator tamper to enroll the translator into the panel (For
Honeywell® and 2GIG®
panels select loop 1).
-or-
• Enter translator ID into panel. The translator’s base ID is printed on the bar code label and ends with a 0.
B
Enroll Zones into panel (not required for Cryptix® (
TM
) Installations)
• With the cover open, trip each zone to enroll into to the panel (For
Honeywell® and 2GIG®
panels select loop 1).
-or-
• Enter ID into panel. The zone ID is the translator’s base ID with the last digit replaced with zone number 1-8.
C
Finish setup of each zone at the panel.
Features
FINISH
A
Close the cover. Test and verify proper operation of the sensors at the panel.
B
Cut the lock wire to lock the translator (For more information on locking, refer to Advanced Setup, step 4).
C
Secure cover with screw.
WIRING DIAGRAM
Wall mounting
screw locations
MOUNT AND WIRE
A
Select a mounting position and location.
B
Wire the zones.
C
Connect 12VDC output to powered zones, if any.
D
Connect the power supply to the translator.
•
Translator has a 90 second lockout after power up.
1
2
3
4
Quick Setup
TRANSLATOR CONFIGURATION
A
Select the brand of panel that the translator must
talk to using the “PANEL SELECT” knob.
B
Configure Zones.
• No zone configuration is necessary for installations with normally
closed zones that don’t require tamper detection.
• Installations with other zone types: Refer to the
(Mounting hardware not included. Use two
#4 or # 6 screws for mounting )
Wall Tamper
(Do not overtighten
mounting screw)
Installation Guide: RE508X & RE508XC Universal Hardwire Translator™