background image

Rev. 041414

More than just power.

TM

VertiLine563V 

Rack Mount Power Supply/Charger

Installation Guide

Z1409

Summary of Contents for VertiLine563V

Page 1: ...Rev 041414 More than just power TM VertiLine563V Rack Mount Power Supply Charger Installation Guide Z1409 ...

Page 2: ...ack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer b Installation of the equipment in a rack should be such that the amount of airflow required for safe operation of the equipment...

Page 3: ...Bridge16PCRX Input 2 to VertiLine563V terminals marked OUT2 Fig 1 pg 2 Fig 5 pg 6 carefully observing polarity 8 When batteries are not used a loss of AC will result in the loss of output voltage When the use of stand by batteries is desired they must be lead acid or gel type Connect four 4 12VDC batteries wired in series to terminals marked BAT Fig 1 pg 2 carefully observing polarity 9 Plug power...

Page 4: ...tachable 2b 56VDC 3A per output 2c Stand by battery connections Maximum charge current 0 3A 2a 2c 2b Fig 3 VertiLine563V configured with two 2 56VDC devices and four 4 12VDC stand by batteries 56VDC Device Altronix VertiLine563V rear Four 4 12VDC batteries optional Input 56VDC Device Input ...

Page 5: ...ine563V configured with two 2 eBridge4PCRX and four 4 12VDC stand by batteries wired in series optional Altronix eBridge4PCRX rear Altronix eBridge4PCRX rear Altronix VertiLine563V rear Four 4 12VDC batteries optional Input Input ...

Page 6: ...d RE2 Rack Battery Enclosure optional Data In Data In Altronix eBridge16PCRX rear Altronix VertiLine563V rear Altronix RE2 rear with four 4 12VDC 7AH batteries Altronix model BT126 Data In Data In 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Input 1 Input 2 BAT4 BAT3 BAT2 BAT1 ...

Page 7: ...ts A on the left and right side of rack chassis using four 4 flat head screws B included Fig 7a 2 Place unit at desired location and secure with mounting screws not included Fig 7b Caution It is necessary to make sure mounting screws are securely fastened to a beam when installing the unit vertically Fig 7b Fig 7 Fig 7a Shelf Installation 1 Position and affix rubber pads C included at each corner ...

Page 8: ...8 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIVertiLine563V G24R MEMBER Rack Mechanical Drawing and Dimensions H x W x D approx 1 625 x 19 125 x 8 5 41 3mm x 485 8mm x 216mm Fig 9 8 5 216mm 0 75 19 05mm TOP BOTTOM 19 125 486mm 17 625 448mm 1 625 41 3mm 8 5 216mm ...