- 2 -
Trove / CDVI
Overview:
Trove1C1, Trove2CV2 and Trove3CV3 accommodate various combinations of CDVI boards with or without Altronix power supplies and
accessories for access control systems.
Specifications:
• 16 Gauge backplane and enclosure with ample knockouts for convenient access.
Agency Listings:
• UL 294 - 6th edition: Line Security I, Destructive Attack I, Endurance IV, Stand-by Power II*.
* Stand-by Power Level I if no battery is supplied.
• This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada.
• CE European Conformity.
Installation Instructions for Trove1, Trove2, Trove3:
1. Remove backplane from enclosure prior to mounting (do not discard hardware).
2.
Trove1C1 (Pg. 8):
Mark and predrill holes on the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in
the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws; level and secure.
Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners.
Place the enclosure’s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws.
Trove2CV2 and Trove3CV3 (Pg. 10 and Pg. 12):
Mark and predrill holes on the wall to line up with the top three keyholes in the enclosure.
Install three upper fasteners and screws in the wall with the screw heads protruding.
Place the enclosure’s upper keyholes over the three upper screws; level and secure.
Mark the position of the lower three holes. Remove the enclosure. Drill the lower
holes and install the three fasteners. Place the enclosure’s upper keyholes over the
three upper screws. Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch(es) (Altronix Model TS112 or equivalent)
in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of
the enclosure approximately 2” from the right side (Fig. 1, pg. 2).
Connect tamper switch wiring to the Access Control Panel input or the appropriate
UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4. Mount Altronix/CDVI modules to TC1, TCV2 or TCV3 backplane, refer to pages 3, 4, 5.
Fig. 1
Trove1C1
Trove1 enclosure with
TC1 Altronix/CDVI backplane
• Includes: tamper switch, cam lock,
and mounting hardware.
Enclosure Dimensions (H x W x D):
18” x 14.5” x 4.625”
(457mm x 368mm x 118mm).
TC1
Altronix/CDVI backplane only
• Includes mounting hardware.
Dimensions (H x W x D):
16.625” x 12.5” x 0.3125”
(422.3mm x 317.5mm x 7.9mm).
TC1 accommodates a combination
of the following:
Altronix Modules:
• One (1) AL400ULXB2, AL600ULXB,
AL1012ULXB, AL1024ULXB2,
eFlow4NB, eFlow6NB, eFlow102NB or
eFlow104NB.
• One (1) ACM4(CB), MOM5, PD4UL(CB),
PD8UL(CB), PDS8(CB), VR6.
CDVI Modules:
• Four (4) A22K/A22NB/ADH10 modules.
Trove2CV2
Trove2 enclosure with
TCV2 Altronix/CDVI backplane
• Includes: tamper switch, cam lock,
and mounting hardware.
Enclosure Dimensions (H x W x D):
27.25” x 21.75” x 6.5”
(692.15mm x 552.5mm x 165.1mm).
TCV2
Altronix/CDVI backplane only
• Includes mounting hardware.
Dimensions (H x W x D):
25.375” x 19.375” x 0.3125”
(644.5mm x 482.6mm x 7.9mm).
TCV2 accommodates a combination
of the following:
Altronix Modules:
• Two (2) AL400ULXB2, AL600ULXB,
AL1012ULXB, AL1024ULXB2,
eFlow4NB, eFlow6NB, eFlow102NB or
eFlow104NB.
• One (1) ACM8(CB), or two (2) MOM5,
PD4UL(CB), PD8UL(CB), PDS8(CB),
VR6.
CDVI Modules:
• Five (5) A22K/A22NB/ADH10 modules.
Trove3CV3
Trove3 enclosure with
TCV3 Altronix/CDVI backplane
• Includes: two (2) tamper switches, cam
lock, and mounting hardware.
Enclosure Dimensions (H x W x D):
36.12” x 30.125” x 7.06”
(917.5mm x 768.1mm x 179.3mm).
TCV3
Altronix/CDVI backplane only
• Includes mounting hardware.
Dimensions (H x W x D):
34” x 28” x 0.3125”
(863.6mm x 711.2mm x 7.9mm).
TCV3 accommodates a combination
of the following:
Altronix Modules:
• Up to four (4) AL400ULXB2,
AL600ULXB, AL1012ULXB,
AL1024ULXB2, eFlow4NB, eFlow6NB,
eFlow102NB or eFlow104NB.
• Up to four (4) ACM8(CB), MOM5,
PD4UL(CB), PD8UL(CB), PDS8(CB),
VR6.
CDVI Modules:
• Ten (10) A22K/A22NB/ADH10 modules.
Tamper Switch
(provided)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure