Altronix Pace4PRM Installation Manual Download Page 1

Long Distance Ethernet Solution

Installation Guide

Models Include:

Pace4PRM

  - Four (4) Channel Receiver

Pace8PRM

  - Eight (8) Channel Receiver

Pace16PRM

  - Sixteen (16) Channel Receiver

Rev. 072914  

More than just power.™

I.T.E.  43KC

Z1409

Summary of Contents for Pace4PRM

Page 1: ...ance Ethernet Solution Installation Guide Models Include Pace4PRM Four 4 Channel Receiver Pace8PRM Eight 8 Channel Receiver Pace16PRM Sixteen 16 Channel Receiver Rev 072914 More than just power I T E 43KC Z1409 ...

Page 2: ...ting the CAT5 from Pace1PTM will not disable the PoE compliant voltage from the Pace4 8 16PRM Although the Pace1PTM can be reconnected caution should be taken not to connect the CAT5 wiring from Pace4 8 16PRM to any non PoE device 1 Pace4 8 16PRM installation a Pace4PRM Affix rubber pads to Pace4PRM for shelf installation Fig 5 pg 6 Pace8 16PRM Attach mounting brackets to Pace8 16PRM unit for rack...

Page 3: ...nd processing equipment is insufficient in speed the image may show pixelation and latency It is advisable to pretest system if unsure Alternatively frame rate and resolution may be reduced to accommodate system equipment Fig 1 Pace8PRM Fig 1a Pace16PRM Fig 2 Pace1PTM Pace1ST OUT Ports 1 4 IN OUT Ports 5 8 IN Pace8PRM front Structured Cable from midspan endspan CAT5 Cable to Pace1PTM OUT Ports 5 8...

Page 4: ... 5 8 IN PoE Camera PoE Camera PoE Camera PoE Camera PoE compliant 100m max PoE compliant 100m max PoE compliant 100m max PoE compliant 100m max Pace1PTM Pace1PTM Pace1PTM Pace1PTM PoE Camera PoE Camera PoE Camera PoE Camera PoE compliant 100m max PoE compliant 100m max PoE compliant 100m max PoE compliant 100m max Pace1PTM Pace1PTM Pace1PTM Pace1PTM Multiple PoE Camera Connection Pace8PRM shown Pa...

Page 5: ...ºF to 158ºF For 30W 40ºC to 60ºC 40ºF to 140ºF Relative humidity 20 to 85 non condensing Storage Temperature 40ºC to 75ºC 40ºF to 167ºF Operating Altitude 304 8 to 2 000m Pace1ST For 15W 40ºC to 75ºC 40ºF to 167ºF For 30W 40ºC to 49ºC 40ºF to 120ºF Relative humidity 20 to 85 non condensing Storage Temperature 40ºC to 75ºC 40ºF to 167ºF Operating Altitude 304 8 to 2 000m Regulatory Compliance UL cU...

Page 6: ...Place unit into desired EIA 19 rack position and secure with mounting screws not included Fig 4c Fig 4 Fig 4a Fig 4b Fig 4c Shelf Installation 1 Position and affix rubber pads C included at each corner on the bottom of the unit Fig 5 2 Place unit in desired location Fig 5 B A C Mounting Hardware Included C A B Top Top Top Front Left Front Left Front Left Left Side Rubber Pad Two 2 mounting bracket...

Page 7: ...Pace4 8 16PRM 7 8 42 213 9mm 5 25 133 35mm 1 7 43 8mm OUT Ports 1 4 IN Enclosure Dimensions H x W x D approximate 1 7 x 5 25 x 8 42 43 8mm x 133 35mm x 213 9mm Pace4PRM ...

Page 8: ...ite www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIPace4 8 16PRM H08Q MEMBER 8 5 216mm 0 75 19 05mm 19 125 486mm 17 625 447 7mm 1 625 42mm OUT Ports 5 8 IN OUT Ports 9 12 IN OUT Ports 13 16 IN OUT Ports 1 4 IN Enclosure Dimensions H x W x D approximate 1 625 x 19 125 x 8 5 42mm x 486mm x 216mm Pace16PRM shown Pace8PRM is similar ...