Altronix Maximal series Installation Manual Download Page 1

Rev. SCB110912

 

     Series

Access Power Controllers

Installation Guide

Models Include:

Maximal3D

- 12VDC @ 5 amp or 24VDC @ 5.4 amp.
- Sixteen (16) PTC protected Class 2 Rated power-limited outputs.

 

Maximal5D

- 12VDC @ 9 amp.
- Sixteen (16) PTC protected Class 2 Rated power-limited outputs.

Maximal7D

- 24VDC @ 9.4 amp.
- Sixteen (16) PTC protected Class 2 Rated power-limited outputs.

Altronix Corp.

140 58th St. Brooklyn, NY

More than just power.

TM

Summary of Contents for Maximal series

Page 1: ...24VDC 5 4 amp Sixteen 16 PTC protected Class 2 Rated power limited outputs Maximal5D 12VDC 9 amp Sixteen 16 PTC protected Class 2 Rated power limited outputs Maximal7D 24VDC 9 4 amp Sixteen 16 PTC pro...

Page 2: ...Access Power Controller Terminal Identification 6 Power Supply Board Stand by Battery Specifications 7 Power Supply Board Output Voltage Settings 7 Access Power Controller Typical Application Diagram...

Page 3: ...d and electronically regulated power outputs b Sixteen 16 Fail Secure filtered and electronically regulated power outputs c Any combination of the above Sixteen 16 Access Control System trigger inputs...

Page 4: ...DC and Maximal7D power supply is factory set at 24VDC 4 Measure the output voltage of the unit before connecting any devices to ensure proper operation Improper or high voltage will damage these devic...

Page 5: ...rocedure below Normally Open Input Placing a short between terminals marked T and INP will trigger the Fire Alarm Disconnect Remove the short to reset Normally Closed Input Remove the wire from termin...

Page 6: ...ized when DC power is present Contact rating 1 amp 28VDC A removed battery is reported within 5 minutes Battery reconnection is reported within 1 minute Low battery threshold 12VDC output threshold se...

Page 7: ...n 12VDC 40AH N A 5 0 amp N A 24VDC 40AH N A 5 4 amp 0 7 amp Maximal5D AL1012ULXB Factory set at 12VDC 12VDC 12AH 9 0 amp Battery capacity for emergency stand by at least 20 min N A Maximal7D AL1024ULX...

Page 8: ...t NO C NC FACP J2 J1 NC C NO COM OUTPUT 1 LED1 F1 NC C NO COM OUTPUT 2 IN GND 1 IN GND 2 IN GND 3 IN GND 4 IN GND 5 IN GND 6 IN GND 7 MAIN IN GND 8 LED2 LED3 LED4 LED5 LED6 LED7 LED8 J2 J1 TRG NC C NO...

Page 9: ...VDC operation only a single battery is needed Connect red battery lead to terminal marked BAT and to the positive terminal of the battery Connect black battery lead to terminal marked BAT and to the n...

Page 10: ...G N Earth Ground Line Neutral 115VAC Input 60 Hz Tamper Switch 24VDC operation Connect two 2 12VDC batteries in series 12VDC Rechargeable Battery Optional 12VDC Rechargeable Battery Optional Fig 4 Ma...

Page 11: ...require different conduit knockouts to be used Any conduit knockouts may be used For power limited applications use of conduit is optional All field wiring connections must be made employing suitable...

Page 12: ...require different conduit knockouts to be used Any conduit knockouts may be used For power limited applications use of conduit is optional All field wiring connections must be made employing suitable...

Page 13: ...require different conduit knockouts to be used Any conduit knockouts may be used For power limited applications use of conduit is optional All field wiring connections must be made employing suitable...

Page 14: ...ACE N C RESET SWITCH N O TRIGGER INPUT JUMPER NO C NC FACP Hook up Diagrams Fig 9 Normally Open Non Latching FACP trigger input Fig 10 Normally Open FACP Latching trigger input with reset This output...

Page 15: ...50 8mm 4 101 6mm 7 177 8mm 4 101 6mm 1 25 31 75mm 6 25 158 75mm 2 5 63 5mm 7 177 8mm 8 5 215 9mm 7 177 8mm 13 5 342 9mm 21 533 4mm 1 25 31 75mm 6 25 158 75mm 1 25 31 75mm 2 50 8mm 4 101 6mm 4 101 6mm...

Page 16: ...TC Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warran...