background image

MaxFit7F8AP

8 Door Kit with Fused Outputs 

Fully assembled kit includes:

  -  One (1) eFlow104NB - Power Supply/Charger
  -  One (1) ACM8 - Fuse Protected Access Power Controller
  -  One (1) PD8UL - Fuse Protected Power Distribution Module
  -  BC750 enclosure

MaxFit7F16AP

16 Door Kit with Fused Outputs 

Fully assembled kit includes:

  -  One (1) eFlow104NB - Power Supply/Charger
  -  Two (2) ACM8 - Fuse Protected Access Power Controllers
  -  One (1) PD16W - Fuse Protected Power Distribution Module
  -  BC750 enclosure

MaxFit7F8APS

8 Door Kit with Fused Outputs 

Fully assembled kit includes:

  -  One (1) eFlow104NB - Power Supply/Charger
  -  One (1) ACM8 - Fuse Protected Access Power Controller
  -  One (1) PDS8 -  Dual Input Fuse Protected 
    Power Distribution Module
  -  One (1) VR6 - Voltage Regulator
  -  BC750 enclosure

MaxFit7F16APS

16 Door Kit with Fused Outputs 

Fully assembled kit includes:

  -  One (1) eFlow104NB - Power Supply/Charger
  -  Two (2) ACMS8 - Dual Input Fuse Protected 
    Access Power Controllers
  -  One (1) VR6 - Voltage Regulator
  -  One (1) PD16W - Fuse Protected Power Distribution Module. 
  -  BC750 enclosure

Fused Access Power Controller Kits

Models Include:

Rev. MFKF_083019

Installing Company:  _________________________ Service Rep. Name:  __________________________________________ 

Address:  _________________________________________________________  Phone #:  _________________________

More than just power.™

Installation Guide

Summary of Contents for MAXIMAL FIT MaxFit7F8AP

Page 1: ...upply Charger One 1 ACM8 Fuse Protected Access Power Controller One 1 PDS8 Dual Input Fuse Protected Power Distribution Module One 1 VR6 Voltage Regulator BC750 enclosure MaxFit7F16APS 16 Door Kit wit...

Page 2: ...4A 16 16 15A 32V 3A 32V 3 5A 250V Installation Instructions Wiring methods shall be in accordance with the National Electrical Code NFPA 70 ANSI and with all local codes and authorities having jurisdi...

Page 3: ...ections power limited ACM8 Outputs to Devices non power limited PD8UL Outputs to Devices non power limited Connect red battery lead to the terminal marked BAT and to the positive terminal of the batte...

Page 4: ...ad to the terminal marked BAT and to the positive terminal of the battery Connect black battery lead to terminal marked BAT and to the negative terminal of the battery Keep power limited wiring separa...

Page 5: ...battery Keep power limited wiring separate from non power limited Use minimum 0 25 spacing 12AH Rechargeable batteries are the largest batteries that can fit in this enclosure A UL listed external ba...

Page 6: ...ed DC Output non power limited Supervisory Connections power limited PD16W Outputs to Devices non power limited ACMS8 Outputs to Devices non power limited ACMS8 Outputs to Devices non power limited Co...

Page 7: ...e Total Cost of Ownership TCO as well as creat ing a new source of Recurring Monthly Revenue RMR LINQ2 Features UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow po...

Page 8: ...1 50 38 1mm 6 25 158 8mm 1 25 31 8mm 1 25 31 8mm 7 00 177 8mm 7 00 177 8mm 7 00 177 8mm 7 00 177 8mm 1 25 31 8mm 1 25 31 8mm 16 50 419 1mm 1 25 31 8mm 0 75 19 1mm 0 569 14 5mm 1 00 25 4mm 1 25 31 8mm...