Altronix AL1012ULACMCB Installation Manual Download Page 1

ACMCB Series

Access Power Controllers
with Power Supplies
Installation Guide

Models Include:

AL400ULACMCB

AL600ULACMCB

-

4 amp @ 12VDC 

-

6 amp @ 12VDC or 24VDC.

or 3 amp @ 24VDC.

-

PTC  Outputs

-

PTC  Outputs

AL1012ULACMCB

AL1024ULACMCB

-

10 amp @ 12VDC. 

-

10 amp @ 24VDC.

-

PTC  Outputs

-

PTC Outputs

Rev. 092503

For a red enclosure, add an “R” suffix to the part # e.g. AL600ULACMCBR

 

 

 

 

 

 

 

  

 

Summary of Contents for AL1012ULACMCB

Page 1: ...uide Models Include AL400ULACMCB AL600ULACMCB 4 amp 12VDC 6 amp 12VDC or 24VDC or 3 amp 24VDC PTC Outputs PTC Outputs AL1012ULACMCB AL1024ULACMCB 10 amp 12VDC 10 amp 24VDC PTC Outputs PTC Outputs Rev...

Page 2: ...Secure power outputs Eight 8 auxiliary power outputs unswitched PTC protected outputs are rated 2 5 amp ACM8CB board main fuse is rated at 10 amp Red LEDs indicate outputs are triggered relays energiz...

Page 3: ...et output voltage AL400ULACMCB and AL600ULACMCB set desired DC output voltage by setting switch SW1 to the appropriate position on the power supply board AL1012ULACMCB is 12VDC and AL1024ULACMCB is 24...

Page 4: ...latching hook up Fig 8 pg 8 c FACP Signaling Circuit input trigger Connect the positive and negative from the FACP signaling circuit output to the terminals marked INP Connect the FACP EOL to the ter...

Page 5: ...or DC POWER SUPPLY req d FACP Fire Alarm Control Panel UL Listed POWER SUPPLY For this application corresponding fuse F8 must be removed SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 FACP Interface Enabled FACP In...

Page 6: ...IL BAT FAIL Battery and AC Supervision Circuit power limited Battery connection non power limited Door Wire Strap from Enclosure to Door DC Output to devices power limited Fire Alarm Interface Insulat...

Page 7: ...approximately 21VDC N A for AL1012ULACMCB BAT Stand by battery connections AL400ULXB AL600ULXB and AL1012ULXB Power Supply Board maximum charge current is 7 amp AL1024ULXB Power Supply Board maximum c...

Page 8: ...ching FACP trigger input with reset This output has not been evaluated by UL Fig 4 Polarity reversal input from FACP signaling circuit output polarity is referenced in alarm condition Fig 3 Optional h...

Page 9: ...arm ______________________ A G Alarm duration Hours example 15 Min 25 Hour Alarm ______________________ H H Battery capacity required for Alarm E F G ______________________ AH I Total calculated batte...

Page 10: ...10 ACMCBseries 875 1 0 0 0 0 10 75 1 5 6 10 5 2 0 1 25 4 5 12 15 5 4 5 4 5 1 25 1 25 14 25 13 5 10 6 625 TOP BOTTOM Enclosure Dimensions 15 5 H x 12 W x 4 5 D...

Page 11: ...ACMCBseries 11 Notes...

Page 12: ...Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIACMCB series L06G MEMBER Altronix is not responsi...