Altronics Q2005 Instuction Manual Download Page 1

AUDIO IMPEDANCE TESTER

INSTUCTION MANUAL

1. INTRODUCTIN

WARNING!

read " SAFETY NOTES " before using the meter.

2. SAFETY NOTES

      1. Read the following safety information carefully before

          attempting to operate or service the meter.

      2. Use the meter only as specified in this manual, otherwise

          the protection provided by the meter may be impaired.

      3. Rated environmental conditions:

          a. Indoor use

          b. Installation CAT III 100V.

          c. Pollution Degree 2.

          d. Altitude up to 2000 Meter.

          e. Relative Humidity 80% Max.

          f.  Ambient Temperature 0

*

~40

*

.

      4. Observe the international electrical symbols listed below:

                   Meter is protected throughout by double insulation or

                   reinforced insulation.

                   Warning!  Risk of electric shock.

                   Caution!  Refer to this manual before using the meter.

           Note        Do not use on live system.

3. FEATURES

      1. True measurement of speaker systems actual impedance

          at1kHz

      2. Three test ranges (20

*

/200

*

/2000

*

) allow testing of

          home theater and commercial sound systems.

      3. Convenient portable battery operation.

      4. Low battery indication

      5. Data hold function.

      6. Timer function for continuous hands free operation. The

          timer can last about 3-5 minutes when users press TEST

          ON/OFF button.

4. SPECIFICATIONS

     1.  Measurement range:

  20

*

/200

*

/2000

*

      2. Test frequency:

          1kHz

      3.  Accuracy:

           20

*

*

2%rdg

*

2dgt  or 

*

0.1

*

, which is greater.

           200

*

/2000

*

*

2%rdg

*

2dgt

      4.  Protection:

           Meets IEC-1010 (EM61010). Installation CAT III 100V

      5.  Power requirement:

           9V DC (6

*

1.5V "AA" UM-3 batteries)

      6.  Dimensions:

           168(L)

*

110(W)

*

60(D) mm

      7.  Included Accessories:

           Test leads, instruction manual, carry case

      8.  Low battery indication:

           " 

 " Symbol appears on the display

     9.  Data hold indication:

          "  HOLD  " Symbol appears on the display

     10. Display:

          LCD 3  1/2 digit (2000 counts)

     11. Weight:

 Approx. 550g (battery included)

5. MEASURING METHODS

      BEFORE PROCEEDING MEASUREMENT, READ SAFETY

      NOTES.

      1.  Ensure the system under test is not live.

      2.  In proceeding with measurement, if " 

 " symbol

           appears on the display, replace with new batteries.

      3.  Rotary the function switch to suitable range then press

           the pushbutton to test and take the reading.

      4.  A drawing of the system should be made before testing

           so the measurement can be attributed to network.

      5.  Measure system power-an 10W up

                                 P=ZI

2

                                 P=V

2

/ Z

           For example on a 100V system:

           If P=50W,  Z=V

2

/ P=100

2

/ 50=200

*

           a. The tester can measure load down to 2k

*

. (10W at

               100V line).

           b. The tester can't measure 100V system with power

               lower than 10W.

      6.  Checking a speaker:

           Speakers are general from 2

*

 to 16

*

, use 20

*

 range or

           for higher impedance speaker, use 200

*

 or 2000

*

 range.

7.  Checking a PA system:

     For example on a PA system. using a 100V configuration.

     a. If Z measured is lower, check for short-circuited wires

         or faulty speakers or transformers.

     b. If Z measured is higher, check for wiring or

         components (Speakers, teansformers or connections).

6.  MAINTENANCE

      1.  Battery Replacement:

           When the symbol " 

 " appears on the display, replace

           with new batteries. As follows:

           a. Disconnect the test leads from the instrument and turn

               off the power.

           b. Use a screwdriver to unscrew the screws on back

               cover then slide the cover, take out the cover, take out

               the batteries and replace with new batteries type SUM-3.

           c. Place back cover and install the screws.