Altox WBUS-4 v2 Operational Manual Download Page 1

 

 

       

 

  

 

O p e r a t i o n a l   M a n u a l

 

 

 

ALTOX WBUS-4 v2

General Guide for Installation

Install the device as far as possible from metal parts and wiring 

harnesses

.

- Recommendation: connect device supply directly to the OBD-II connector 
wires where pin 16 is +12В, pin 4 is GND (common)

.  

 

 

Auxiliary output OUT commutates at +12V. It is used to start heaters using 

an analogous signal and to connect status LED located in the button from 
the package, as well as to connect a coolant pump or the interior's heater 
via a power relay.
Auxiliary output OUT is switched on with the delay (TIME2 setting) and/or 
based on the coolant agent temperature (LTEMP1 setting) after the heater 
is switched on. It is switched off with the delay (TIME3 setting) after the 
heater is switched off.

If there are other control units on the bus, it is recommended to connect 

the module's control wire (blue) via normally open signaling relay 
controlled by output OUT.
In this case you should activate setting SEPARLINE1 that activates this relay 
before the data exchange.

 

If you need to implement additional options of remote control of output 

OUT (for example, to block engine remotely) activate setting SEPAROUT1. 
It switches the output mode into manual control mode 

(

SMS-commands:

 

ACTIVATE / DEACTIVATE)

.

In this mode setting KEEPOUT1 activates option to save and to 
subsequently restore of output OUT state when the module's power supply 
is switched off and then switched on, respectively.

Please indicate the place of ALTOX module's location in the vehicle for 
possible maintenance

:

Authorized Service

:

Installation Date:

Altox

Summary of Contents for WBUS-4 v2

Page 1: ...hed off with the delay TIME3 setting after the heater is switched off If there are other control units on the bus it is recommended to connect the module s control wire blue via normally open signaling relay controlled by output OUT In this case you should activate setting SEPARLINE1 that activates this relay before the data exchange If you need to implement additional options of remote control of...

Page 2: ...nd the option of using web interface to control the system in the real time mode Control and Programming You can start using your ALTOX module right after you have saved authorized phone numbers in settings 3 cells NUM1 NUM2 NUM3 Saving of the first caller s phone number into cell NUM1 follows up automatically cell NUM1 should be empty To save other phone numbers use a text message command NUMX YYY...

Page 3: ...B not taking rounding off into account To automatically switch off the data transfer in roaming use setting PING2 0 Text SMS with General Settings A0 R1 B0 T30 0 0 HEATER A0 RSTOP1 BIND0 TIME1 2 3 L0 0 F0 S0 0 K0 LTEMP1 2 FIXKEY0 SEPAR OUT0 LINE0 KEEPOUT0 S1 w0 e1 SMSF1 SMSW0 SMSE1 C1 P CALL1 PASS up to 4 characters N1 phone number cell NUM1 N2 phone number cell NUM2 N3 phone number cell NUM3 B 10...

Page 4: ...up the delay time for switching on output OUT using setting TIME2 XX and or set up switching of output OUT based on the coolant temperature using setting LTEMP1 XX where value ХХ can be from 0 to 99 С 0 the setting is OFF 4 LTEMP2 XX setting allows switching the heater off based on the coolant temperature before the operation time TIME1 XX Attention LTEMP1 2 are available not for all heater models...

Reviews: