MN-28871 • Rev 5 • 10/17 • 750-CTUS Hot Food Holding Cabinet 11
Electrical Connections
1. An identification tag is permanently mounted on
the cabinet.
2. Plug cabinet into a properly grounded receptacle ONLY,
positioning the unit so the power supply cord is easily
accessible in case of an emergency.
Arcing will occur when connecting or disconnecting the
unit unless all controls are in the “OFF” position.
3. If necessary, a proper receptacle or outlet configuration
as required for this unit, must be installed by a licensed
electrician in accordance with applicable, local electrical
codes.
NOTICE
:
CE approved appliance must be connected to an
electrical circuit that is protected by an external
GFCI outlet.
CAUTION
Power source must match voltage identified
on appliance rating tag. The rating tag
provides essential technical information
required for any appliance installation,
maintenance or repairs. Do not remove,
damage or modify the rating tag.
WARNING
To prevent serious injury, death, or
property damage:
All electrical connections must be
made by a qualified and trained service
technician in accordance with applicable
electrical codes.
This appliance must be adequately
grounded in accordance with local
electrical codes or, in the absence of local
codes, with the current edition of the
National Electrical Code ANSI/NFPA No.
70. In Canada, all electrical connections
are to be made in accordance with CSA
C22.1, Canadian Electrical Code Part 1 or
local codes.
CE-approved appliances include an
equipotential-bonding terminal marked
with the symbol shown on the left .
Provisions for earthing are to be made in
accordance with IEC:2010 60335-1 section
27 or local codes.
Hard wired models:
Hard wired models must be equipped with a country
certifi ed external allpole disconnection switch with
suffi cient contact separation.
If a power cord is used for the connection of the product an
oil resistant cord like H05RN or H07RN or equivalent must
be used.
Wire diagrams are located inside the top of the unit.
Electrical
V
P
h
h
z
A kW
120 1 50/60 18.8 2.25
nema
l
5-30
p
30a, 125V
plug
208 1 50/60 8.5 1.77
nema
6-15
p
240 1 50/60 9.8 2.25
15a, 250V
plug
230 1
50
9.4 2.17
plugs
rated
250V
as
/
nzs
3112
cee
7/7
bs
1363