Alto-Shaam 10 10 Installation Manual Download Page 1

MN-29245 • 06/10

P R I N T E D I N U

.

S

.

A

.

C o m b i t h e r m

®

C o m b i n a t i o n

O v e n / S t e a m e r

ES ELECTRIC

COM B ITOUCH™

S ERI ES

6•10

10•10

7•14

10•18

12•20

20•20

VHes-5

VHes-10

• I N STALLATION

W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA

PHONE: 262.251.3800 • 800.558.8744

USA

/

CANADA

FAX: 262.251.7067 • 800.329.8744

U

.

S

.

A

.

ONLY

WWW

.

ALTO

-

SHAAM

.

COM

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for 10 10

Page 1: ...SERIES 6 10 10 10 7 14 10 18 12 20 20 20 VHes 5 VHes 10 INSTALLATION W164 N9221 Water Street P O Box 450 Menomonee Falls Wisconsin 53052 0450 USA PHONE 262 251 3800 800 558 8744 USA CANADA FAX 262 251 7067 800 329 8744 U S A ONLY WWW ALTO SHAAM COM All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...ecifications 7 14esi 14 Specifications 10 18es 15 Specifications 10 18esi 16 Specifications 12 20es 17 Specifications 12 20esi 18 Specifications 20 20es 19 Specifications 20 20esi 20 Electrical Connection 21 Drip Tray Installation 23 Mobile Equipment Restraint 23 Water Quality Requirement 24 Water Connections 25 Installation Checklist 26 Combitouch Checklist 27 Error Codes 28 Ventless Hood Option ...

Page 3: ...pliance from the carton or crate NOTE Do not discard the carton and other packaging material until you have inspected the unit for hidden damage and tested it for proper operation 2 Read all instructions in this manual carefully before initiating the installation of this appliance DO NOT DISCARD THIS MANUAL This manual is considered to be part of the appliance and is to be provided to the owner or...

Page 4: ...s must remain with the appliance if the item is sold or moved to another location N O T E Used to notify personnel of installation operation or maintenance information that is important but not hazard related C A U T I O N Used to indicate the presence of a hazard that can or will cause minor personal injury property damage or a potential unsafe practice if the warning included with this symbol is...

Page 5: ...ven AIR SUPPLY ELECTRICAL CONNECTIONS WATER CONNECTIONS AND WASTE WATER DISCHARGE NOTE Where automatically operated appliances are vented through a ventilating hood or exhaust system equipped with a damper or with a power means of exhaust provisions shall be made to allow the equipment to operate only when the damper is open to a position to properly vent the appliance and when the power means of ...

Page 6: ...table open and level Recommended height is 23 inches 584mm Adjust the height of floor models for smooth access of the trolley or cart When positioning the oven observe the minimum space allocation requirements shown To insure proper operation the installation of this oven must be completed by qualified technicians in accordance with the instructions provided in this manual Failure to follow the in...

Page 7: ...th the retractable door option allow a minimum clearance of 6 1 2 inches 165mm Allow a minimum clearance of 4 inches 102mm from the back of the oven for plumbing connections Allow a 20 inch 500mm clearance at the top of the oven for free air movement and for the steam vent s located at the top Do not install the oven adjacent to heat producing equipment such as fryers broilers etc Heat from such a...

Page 8: ... 325mm x 530mm BS 26730 Grilling Grate 12 X 20 325mm x 530mm SH 26731 Shelf Stainless Steel Wire 6 10 10 10 SH 2903 7 14 10 18 SH 22584 12 20 20 20 SH 22473 Probe Sous Vide PR 34747 Combitherm Cleaning Liquid CE 24750 SPECIALLY FORMULATED FOR COMBITHERM OVENS TWELVE 12 CONTAINERS CASE 1 QUART C 1 LITER EACH Combiclean Tablets CE 28892 SPECIALLY FORMULATED FOR COMBITHERM OVENS TWO 2 CONTAINERS BOX ...

Page 9: ...47 0 11 2 at 208 3 60 3 Wire plus ground 23 5 ph 8 5 at 240 AWG 8 27 0 ph 11 2 at 380 3 50 4 Wire plus ground 13 0 ph 8 5 at 415 AWG 12 16 0 ph 11 2 at 440 3 60 3 Wire plus ground 11 2 ph 8 5 at 480 AWG 8 13 5 ph 11 2 ELECTRICAL SERVICE CHARGE APPLIES 2 0 8 2 4 0 2 0 8 2 4 0 3 8 0 4 1 5 4 4 0 4 8 0 CLEARANCE REQUIREMENTS LEFT 6 152mm RECOMMENDED SERVICE ACCESS 18 457mm 20 508mm FROM HEAT PRODUCING...

Page 10: ...plus ground 23 3 ph 8 5 25 0 ph 9 0 at 240 AWG 8 27 0 ph 11 2 28 2 ph 11 7 at 380 3 50 4 Wire plus ground 13 0 ph 8 5 14 0 ph 9 0 at 415 AWG 12 15 6 ph 11 2 16 3 ph 11 7 at 440 3 60 3 Wire plus ground 11 0 ph 8 5 12 0 ph 9 0 at 480 AWG 8 13 0 ph 11 2 14 0 ph 11 7 ELECTRICAL SERVICE CHARGE APPLIES 2 0 8 2 4 0 2 0 8 2 4 0 3 8 0 4 1 5 4 4 0 4 8 0 CLEARANCE REQUIREMENTS LEFT 6 152mm RECOMMENDED SERVIC...

Page 11: ...t 208 3 60 3 Wire plus ground 23 3 ph 8 5 25 0 ph 9 0 at 240 AWG 8 27 0 ph 11 2 28 2 ph 11 7 at 380 3 50 4 Wire plus ground 13 0 ph 8 5 14 0 ph 9 0 at 415 AWG 12 15 6 ph 11 2 16 3 ph 11 7 at 440 3 60 3 Wire plus ground 11 0 ph 8 5 12 0 ph 9 0 at 480 AWG 8 13 0 ph 11 2 14 0 ph 11 7 ELECTRICAL SERVICE CHARGE APPLIES 2 0 8 2 4 0 2 0 8 2 4 0 3 8 0 4 1 5 4 4 0 4 8 0 CLEARANCE REQUIREMENTS LEFT 6 152mm ...

Page 12: ...at 208 3 60 3 Wire plus ground 38 5 ph 13 9 at 240 AWG 6 44 0 ph 18 4 at 380 3 50 4 Wire plus ground 21 5 ph 13 9 at 415 AWG 10 25 6 ph 18 4 at 440 3 60 3 Wire plus ground 20 0 ph 15 4 at 480 AWG 8 22 0 ph 18 4 ELECTRICAL SERVICE CHARGE APPLIES 2 0 8 2 4 0 2 0 8 2 4 0 3 8 0 4 1 5 4 4 0 4 8 0 CLEARANCE REQUIREMENTS LEFT 6 152mm RECOMMENDED SERVICE ACCESS 18 457mm 20 508mm FROM HEAT PRODUCING EQUIPM...

Page 13: ...Wire plus ground 38 6 ph 13 9 40 0 ph 14 4 at 240 AWG 6 44 3 ph 18 4 45 5 ph 18 9 at 380 3 50 4 Wire plus ground 21 1 ph 13 9 22 0 ph 14 4 at 415 AWG 10 25 6 ph 18 4 26 3 ph 18 9 at 440 3 60 3 Wire plus ground 20 0 ph 15 4 21 0 ph 15 9 at 480 AWG 8 22 0 ph 18 4 23 0 ph 18 9 ELECTRICAL SERVICE CHARGE APPLIES 2 0 8 2 4 0 2 0 8 2 4 0 3 8 0 4 1 5 4 4 0 4 8 0 CLEARANCE REQUIREMENTS LEFT 6 152mm RECOMME...

Page 14: ...us ground 38 6 ph 13 9 40 0 ph 14 4 at 240 AWG 6 44 3 ph 18 4 45 5 ph 18 9 at 380 3 50 4 Wire plus ground 21 1 ph 13 9 22 0 ph 14 4 at 415 AWG 10 25 6 ph 18 4 26 3 ph 18 9 at 440 3 60 3 Wire plus ground 20 0 ph 15 4 21 0 ph 15 9 at 480 AWG 8 22 0 ph 18 4 23 0 ph 18 9 ELECTRICAL SERVICE CHARGE APPLIES 2 0 8 2 4 0 2 0 8 2 4 0 3 8 0 4 1 5 4 4 0 4 8 0 CLEARANCE REQUIREMENTS LEFT 6 152mm RECOMMENDED SE...

Page 15: ...ph 18 4 at 440 3 60 3 Wire plus ground 20 0 ph 15 4 at 480 AWG 8 22 0 ph 18 4 ELECTRICAL SERVICE CHARGE APPLIES 2 0 8 2 4 0 2 0 8 2 4 0 3 8 0 4 1 5 4 4 0 4 8 0 CLEARANCE REQUIREMENTS LEFT 6 152mm RECOMMENDED SERVICE ACCESS 18 457mm 20 508mm FROM HEAT PRODUCING EQUIPMENT RIGHT 4 102mm TOP 20 508mm FOR AIR MOVEMENT BACK 4 102mm BOTTOM 5 1 8 130mm FOR LEGS WATER REQUIREMENTS TWO 2 COLD WATER INLETS D...

Page 16: ... 2 x 28 7 8 515mm x 596mm x 722mm ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY INSTALLATION REQUIREMENTS Oven must be installed level Hood installation is required Water supply shut off valve and back flow preventer 7 14ESi CLEARANCE REQUIREMENTS LEFT 6 152mm RECOMMENDED SERVICE ACCESS 18 457mm 20 508mm FROM HEAT PRODUCING EQUIPMENT RIGHT 4 102mm TOP 20 508mm FOR AIR MOVEMENT BACK 4 102mm...

Page 17: ... 3 Wire plus ground 61 3 ph 22 0 at 240 AWG 2 70 0 ph 29 2 at 380 3 50 4 Wire plus ground 33 5 ph 22 0 at 415 AWG 6 40 7 ph 29 2 at 440 3 60 3 Wire plus ground 36 0 ph 27 2 at 480 AWG 6 43 5 ph 36 1 ELECTRICAL SERVICE CHARGE APPLIES 2 0 8 2 4 0 3 8 0 4 1 5 4 4 0 4 8 0 CLEARANCE REQUIREMENTS LEFT 6 152mm RECOMMENDED SERVICE ACCESS 18 457mm 20 508mm FROM HEAT PRODUCING EQUIPMENT RIGHT 4 102mm TOP 20...

Page 18: ... Wire plus ground 61 1 ph 22 0 62 5 ph 22 5 at 240 AWG 2 70 3 ph 29 2 71 5 ph 29 7 at 380 3 50 4 Wire plus ground 33 5 ph 22 0 34 2 ph 22 5 at 415 AWG 8 40 7 ph 29 2 41 4 ph 29 7 at 440 3 60 3 Wire plus ground 35 7 ph 27 2 36 4 ph 27 7 at 480 AWG 8 43 5 ph 36 1 44 0 ph 36 6 ELECTRICAL SERVICE CHARGE APPLIES 2 0 8 2 4 0 3 8 0 4 1 5 4 4 0 4 8 0 CLEARANCE REQUIREMENTS LEFT 6 152mm RECOMMENDED SERVICE...

Page 19: ...08 3 60 3 Wire plus ground 75 6 ph 27 2 at 240 AWG 2 87 0 ph 36 1 at 380 3 50 4 Wire plus ground 41 4 ph 27 2 at 415 AWG 6 36 1 ph 36 1 at 440 3 60 3 Wire plus ground 36 0 ph 27 2 at 480 AWG 6 43 5 ph 36 1 ELECTRICAL SERVICE CHARGE APPLIES 2 0 8 2 4 0 3 8 0 4 1 5 4 4 0 4 8 0 CLEARANCE REQUIREMENTS LEFT 6 152mm RECOMMENDED SERVICE ACCESS 18 457mm 20 508mm FROM HEAT PRODUCING EQUIPMENT RIGHT 4 102mm...

Page 20: ... 27 7 at 240 AWG 2 87 0 ph 36 1 88 2 ph 36 6 at 380 3 50 4 Wire plus ground 41 4 ph 27 2 42 1 ph 27 7 at 415 AWG 6 50 0 ph 35 7 51 0 ph 36 6 at 440 3 60 3 Wire plus ground 36 0 ph 27 2 36 4 ph 27 7 at 480 AWG 6 43 5 ph 36 1 44 0 ph 36 6 ELECTRICAL SERVICE CHARGE APPLIES 2 0 8 2 4 0 3 8 0 4 1 5 4 4 0 4 8 0 CLEARANCE REQUIREMENTS LEFT 6 152mm RECOMMENDED SERVICE ACCESS 18 457mm 20 508mm FROM HEAT PR...

Page 21: ...E CHARGE APPLIES 2 0 8 2 4 0 3 8 0 4 1 5 4 4 0 4 8 0 DIMENSIONS H x W x D EXTERIOR 76 1 4 x 46 3 4 x 48 1936mm x 1186mm x 1218mm EXTERIOR WITH RECESSED DOOR 76 1 4 x 50 3 4 x 48 1936mm x 1288mm x 1218mm INTERIOR 60 1 4 x 26 1 4 x 32 11 16 1530mm x 667mm x 830mm CLEARANCE REQUIREMENTS LEFT 6 152mm RECOMMENDED SERVICE ACCESS 18 457mm 20 508mm FROM HEAT PRODUCING EQUIPMENT RIGHT 4 102mm TOP 20 508mm ...

Page 22: ... 4 at 240 AWG 4 173 9 ph 72 2 176 3 ph 73 2 at 380 3 50 60 4 Wire plus ground 83 0 ph 54 4 84 3 ph 55 4 at 415 AWG 2 101 0 ph 72 2 102 0 ph 73 2 at 440 3 50 60 3 Wire plus ground 71 5 ph 54 4 72 8 ph 55 4 at 480 AWG 2 87 0 ph 72 2 88 2 ph 73 2 ELECTRICAL SERVICE CHARGE APPLIES 2 0 8 2 4 0 3 8 0 4 1 5 4 4 0 4 8 0 CLEARANCE REQUIREMENTS LEFT 6 152mm RECOMMENDED SERVICE ACCESS 18 457mm 20 508mm FROM ...

Page 23: ...ical wiring diagram is located behind the control panel on the left side of the oven This appliance must be branch circuit protected with proper ampacities in accordance with the wiring diagram 2 Wire size for the main incoming power to the unit must match the minimum size listed in the specifications applicable to the specific oven model For supply connections locate the wire size posted on the l...

Page 24: ...EN Terminal Block Ground Electrical Connection D A N G E R To avoid electrical shock this appliance MUST be adequately grounded in accordance with local electrical codes or in the absence of local codes with the current edition of the National Electrical Code ANSI NFPA No 70 In Canada all electrical connections are to be made in accordance with CSA C22 1 Canadian Electrical Code Part 1 or local co...

Page 25: ... apply 1 Casters must be a maximum height of 6 152mm 2 Two of the casters must be the locking type 3 Such mobile appliances or appliances on mobile stands must be installed with the use of a flexible connector secured to the building structure A mounting connector for a restraining device is located on the lower back flange of the appliance chassis or on an oven stand approximately 18 457mm from t...

Page 26: ...with the required levels of steam generating equipment maintenance will help lessen the affect water has on metal surfaces It will not however provide complete protection against all water damage from region to region Due to the complexity of water chemistry it is important to understand that water quality plays a significant role in the longevity of steam producing equipment Water quality and req...

Page 27: ... for flexible hose connection to the COLD water source PIPE SEALING TAPE TEFLON MUST BE USED AT ALL CONNECTION POINTS The use of a pipe sealing compound is not recommended WATER REQUIREMENTS TWO 2 COLD WATER INLETS DRINKING QUALITY ONE 1 TREATED WATER INLET 3 4 NPT ONE 1 UNTREATED WATER INLET 3 4 NPT LINE PRESSURE 30 to 90 psi 2 8 to 6 2 bar Can manifold off of one 3 4 line REFER TO PUBLISHED SPEC...

Page 28: ...ve gradient away from the Combitherm oven and not more than 12 inches 305mm before an air gap NOTE In the U S A this equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of the Food Drug Administration FDA If several units are to be connected to one drain pipe the dimensio...

Page 29: ...N ___________________________ IS A FILTER SYSTEM INSTALLED ON THIS UNIT YES NO STORE HAS SEEN THIS RECOMMENDATION YES NO SIGNATURE OF STORE REPRESENTATIVE ___________________________________________ CONTROL BOARD CONNECTIONS OPERATION With the Power ON press the Set Up Key to access software version and record ALL BOARD CONNECTIONS TIGHT YES NO ALL FUNCTIONS ARE DISPLAYED YES NO ALL FUNCTIONS ON C...

Page 30: ...ection Mode Combi Mode Convection Oven contactor s stuck closed N6 Oven Cavity Temperature probe defective N6 Cavity Probe connection problem Combi Mode Only Insufficient water supply into oven for steam production E13 Boiler Temperature High Boiler temperature overheats Scale build up inside steam generator B4 Probe connection problem B4 probe faulty E15 Condensor Temperature High Excess condenso...

Page 31: ... Fault Condensor water temperature probe defect or disconnected B3 Condensor temperature probe defective B3 Condensor probe connection problem E26 N8 Boiler Safety Temperature Probe Fault Steam generator heating element protection probe defect or disconnected N8 Boiler temperature probe defective N8 probe connection problem E27 Boiler Element Temperature High Excess steam generator safety probe Sc...

Page 32: ...tch micro switch Fault vent valve motor Probe connection problem Fault vent valve safety switch micro switch Wiring or connection problem E57 No rinse water During rinse no water flow is detected trough solenoid valve Water supply is shut off Low water pressure Check wiring to all components mention below Flow switch dirty or defect Double water solenoid valve defective Y3 Relay board high voltage...

Page 33: ...BROWNING Yes NO BROWNING Yes NO BROWNING E36 Steam Temperature High Yes No No No Yes No E40 B3 Condensor Probe Short to Frame Yes Yes No No To 356 F No E41 B4 Boiler Probe Short to Frame Yes No No No Yes No E42 B5 Bypass Probe Short to Frame Yes Yes No No Yes No E43 N6 Cavity Probe Short to Frame Yes Yes BOILER UNITS ONLY No No No E44 N8 Boiler Safety Temperature Probe Short to Frame Yes No No No ...

Page 34: ...ercurrent LED flashing sequence with 4 flashes per period Blocked motor detected by current peak monitoring from 900 rpm rotating field Overcurrent LED flashing sequence with 5 flashes per period Intermediate circuit current exceeds 4 0A Short circuit LED flashing sequence with 6 flashes per period Release of interrupt at intermediate circuit current larger than 53A Power on LED flashing sequence ...

Page 35: ...are circulated through filters draining the condensation through a drain at the rear of the hood An activated charcoal filter cleans the air before venting it out the top of the hood CONDENSATE DRAIN A ventless hood condensate drain line to the floor drain must be installed The 3 4 NPT thread connection is found at the back of the hood The drain line must always be a positive gradient away from th...

Page 36: ...the filter pull and slide out while holding the bottom housing When replacing the filter make certain the air flow arrow s point toward the hood fan and that the filter is replaced in the three sided metal frame provided with the hood FI 24114 VHes 5 FI 24102 VHes 10 Timed Latching Mechanism In order to evacuate steam and grease laden air from the oven interior this mechanism prevents the operator...

Page 37: ...ER NOT MEETING ALTO SHAAM S MINIMUM WATER QUALITY STANDARDS WILL VOID THIS WARRANTY Water quality and required maintenance of steam generating equipment is the responsibility of the owner operator The installation and use of Alto Shaam s CombiGuard Water Filtration System is highly recommended 6 Damage caused by use of any cleaning agent other than Alto Shaam s Combitherm Oven Cleaner including bu...

Page 38: ...claim with the carrier and attach copies of all supporting paperwork We will continue our policy of assisting our customers in collecting claims which have been properly filed and actively pursued We cannot however file any damage claims for you assume the responsibility of any claims or accept deductions in payment for such claims RECORD THE MODEL AND SERIAL NUMBER OF THE APPLIANCE FOR EASY REFER...

Reviews: