C-Clamp Installation

The provided c-clamp should be installed as shown in 

Figure 2

. Only use the hardware supplied with the

c-clamp.

To Install the C-clamp:

1.  With luminaire on a flat, sturdy surface, position yoke assembly for easy access as illustrated in 

Figure 2

.

2.  Place on 1/2-13 hex bolt, in this order, the 1/2-inch lock washer and then the 1/2-inch flat washer.
3.  Insert bolt into hole on yoke assembly.
4.  Position c-clamp over bolt and thread bolt into c-clamp.
5.  Tighten bolt.

Safety Cable Installation

The provided safety cable should be installed in accordance to local and national codes.

NOTE

: The safety cable (supplied with unit) 

should be used and may be required by local 

and/or national codes when hanging this    

luminaire. The mounting structure must be 

capable of supporting the weight of the fixture, 

lens, cabling, any accessories, etc.

C-Clamp
Worklight II Yoke 

1/2-inch (13mm) Mounting Hole

1/2-inch Flat Washer

1/2-inch Lock Washer

1/2-13 Hex Bolt

C-Clamp

Safety Cable Anchor Point

Figure 2: C-Clamp Installation

Summary of Contents for WORK LIGHT II

Page 1: ...USER S MANUAL WORKLIGHTII_USERS_MANUAL_20210702 WORK LIGHT II LED WORKLIGHT LUMINAIRE USER MANUAL ...

Page 2: ...n Altman Lighting uebernimmt keine Verantwortung für Fehler oder Irrtuemer die in diesem Handbuch auftreten FürBemerkungen und Verbesserungsvorschlaege oder Vorschlaege in Bezug auf Korrekturen und oder Aktualisierungen in diesem Handbuch moechten wir Sie bitten Kontakt mit der naechsten Altman Lighting Niederlassung aufzunehmen Should you have a suggestion or question regarding your Altman Lighti...

Page 3: ...to use proper cable can result in damage to equipment or danger to personnel WARNING This equipment is intended for installation in accordance with the National Electric Code and local regulations Before any electrical work is performed disconnect power at the circuit breaker or remove the fuse to avoid shock or damage to the control It is recommended that a qualified electrician perform this inst...

Page 4: ...ignitors ballasts etc Altman will grant the same war ranty given Altman by its vendors Altman assumes no responsibility for damage or faulty performance caused by misuse improper installation careless handling or where repairs have been attempted by others This warranty is in lieu of all warranties or guarantees expressed or implied and no representative or person is authorized to assume Altman an...

Page 5: ... Table Of Contents 5 Installation And Setup 6 Power Requirements 6 Connecting Power 6 Mains Dimming 6 Mounting 7 Adjusting Tilt 7 Installing C Clamp 8 Installing Safety Cable 8 Cleaning and Care 9 Special Cleaning and Care Instructions 9 Service and Maintenance 9 Troubleshooting 10 Troubleshooting Guide 10 Specifications 11 ...

Page 6: ...Earth Ground Live Table 1 AC Input Wiring The WorkLight can be wired into a Phase Cut or Triac Dimmer On each unit there is a Local Dim dial that will allow to locally dim the unit when connected to constant power Mains Dimming Dimming Notes The WL 90 is designed as a set it and forget it luminaire that employs a local dim control and mains dim compatible power supply When running on mains dim pow...

Page 7: ... kilograms Adjusting Tilt The LED Work Light can have its tilt adjusted via the two lock off handles on each side of the luminaire refer to Figure 1 Simple loosen but DO NOT REMOVE each handle so the unit is able to swing up and down Set tilt as desired and re tighten the two lock off handles so the unit does not move from the set position Luminaire Yoke Assembly Safety Cable Anchor Point Hinged A...

Page 8: ...ole on yoke assembly 4 Position c clamp over bolt and thread bolt into c clamp 5 Tighten bolt Safety Cable Installation The provided safety cable should be installed in accordance to local and national codes NOTE The safety cable supplied with unit should be used and may be required by local and or national codes when hanging this luminaire The mounting structure must be capable of supporting the ...

Page 9: ...n as described herein alterations unauthorized service etc will void the product warranty Contact your local Altman Lighting office Special Cleaning and Care Instructions Being a solid state fixture and unlike most fixtures the LED Work Light requires very little routine maintenance by the user If you have any questions regarding the use or care of your LED Work Light please contact Altman Lightin...

Page 10: ...t light and connected to power Check to see that the Local Dim Switch is set to anything above zero When plugged into a Dimmer the Local Dim Switch needs to be at Full Low light output Fixture produces low light output and connected to power Check to see that the Local Dim Switch is set above zero When plugged into a Dimmer the Local Dim Switch needs to be at Full Make sure that the output of the ...

Page 11: ...z Wattage Wattage 90 Watts LED Engine Cooling LED Engine Cooling Convection passive Convection passive Color Options Color Options Black or White Custom colors consult factory Black or White Custom colors consult factory Environment Environment 0 40 C 32 104 F with humidity of 5 95 0 40 C 32 104 F with humidity of 5 95 non condensing non condensing Weight Weight 11 lbs 4 98 kg 11 lbs 4 98 kg Compl...

Reviews: