Page 8
Hydra Series AIP-200 LED Luminaires
Installation & Users Manual
Power Requirements
Before performing any field wiring, refer to and read the warnings contained in “Important Infor-
mation” on page 4.
WARNING! AIP-200 should be connected to a constant circuit or a relay device. It should never
be connected to a dimmer or circuit controlled by a dimmer.
WARNING! The maximum allowable input current is 16 Amps. Do not overload circuits! Lumi-
naires must be supplied by a branch circuit protected by a maximum 16 Amp circuit protector.
Doit être alimenté par un circuit de dérivation protégé par un maximum de 16 ampères circuit
protecteur. Ne surchargez pas les circuits!
WARNING! When using the daisy-chain connection method, only connect your AIP-200 RGBL
Par LED Luminaire to AC Output Connection of other AIP-200 RGBL Par LED Luminaires. DO
NOT CONNECT OTHER TYPES OF LUMINAIRES OR DEVICES! The maximum allowable of num-
ber of AIP-200 RGBL Par LED Luminaires that can be daisy-chained on one power feed should
not exceed the first fixture’s 16 Amp power rating.
Connecting Power
Units are powered via an AC input cable (sold separately, refer to “Accessories” on page 6 for optional
AC input cables) from 100 to 240VAC, 50/60Hz and draw approximately 200 Watts of power. The table be-
low outlines the wire colors and their purpose.
WIRE COLOR
PURPOSE
Brown or Black
Main / (L)ine
Blue or White
(N)eutral
Gren/Yellow or Green
Ground / Earth
The AIP-200 Luminaire must be connected to and properly grounded to an
viable earth ground.
Connector Wiring
Male Connector
Female Connector
AIP-200 utilizes Seetronic PowerKon 16 amp IP65 rated connectors.
Recommended stripping lengths