MANUAL PART NUMBER: 400-0117-001
PRODUCT REVISION: 1

TNP100UKUN

Tilt ‘N Plug™ Interconnect Box

FOR THE UNITED KINGDOM

USER'S GUIDE

Summary of Contents for Tilt `N Plug Interconnect Box TNP100UK

Page 1: ...ACCESSORIES MANUAL PART NUMBER 400 0117 001 PRODUCT REVISION 1 TNP100UKUN Tilt N Plug Interconnect Box FOR THE UNITED KINGDOM USER S GUIDE ...

Page 2: ...ECHNICAL SPECIFICATIONS 3 TNP100UK DIMENSIONS 4 DIAGRAMS 1A 1D 4 DESCRIPTION DIAGRAM 5 DIAGRAM 2 5 APPLICATION DIAGRAM 6 DIAGRAM 3 6 DIAGRAM 4 7 DIAGRAM 5 8 INSTALLATION 9 OPERATION 10 FREQUENTLY ASKED QUESTIONS 10 CABLES AND ACCESSORIES 11 TROUBLESHOOTING GUIDE 12 ALTINEX POLICY 12 LIMITED WARRANTY 12 RETURN POLICY 12 CONTACT INFORMATION 12 ...

Page 3: ...er disconnect the power cord which powers the power socket on the TNP100UK pop up panel only The power outlet socket should be installed as near to the equipment as possible and should be easily accessible We recommend using wall outlets with a Ground Fault Circuit Interrupter GFCI for maximum protection Install all cables according to the instructions Do not force or pull out any cable or power c...

Page 4: ...tors or cables For additional information regarding optional connectors contact the ALTINEX Sales Department The Tilt N Plug Interconnect Box is designed for use with tables ranging from one to three inches thick It offers an optional mounting bezel to secure the unit flush with the table s surface The Tilt N Plug comes in a standard matte black color The top of the unit can be finished to match t...

Page 5: ...ACCESSORIES 4 TNP100UK DIMENSIONS 4 Diagrams 1A 1B 1C 1D ...

Page 6: ...ACCESSORIES 5 DESCRIPTION DIAGRAM 5 Diagram 2 Label of Product ...

Page 7: ...ACCESSORIES 6 APPLICATION DIAGRAM 6 Diagram 3 Application ...

Page 8: ...ACCESSORIES 7 Diagram 4 Final Installation ...

Page 9: ...ACCESSORIES 8 Diagram 5 Table Cutout Requirements ...

Page 10: ...les by using the provided cable clamp See Figure 2 Pass the power cord from the bottom of the housing and attach it to the table using the cable clamp supplied with the TNP100UK unit Do not keep the cord too tight or too loose See Diagram 4 page 7 Figure 2 Cable Clamp Step 5 Connect the appropriate cables with the correct input connectors There are two RCA audio connectors on the front panel of th...

Page 11: ...hat do I do if the TNP100UK won t stay open Replace the gas spring Call ALTINEX for service information 5 How much room is taken up on the underside of the table The unit is 4 5 inches deep maximum below the table to this dimension add about 2 5 inches for cable clearance 6 What if my table is thicker than 3 inches Then the area under the table near the TNP100UK must be reduced to 3 inches of thic...

Page 12: ...M FLEX MULTI CHANNEL COAX CABLE VGA MALE TO VGA FEMALE HD 15 CB5000PL 5VMxxxx5VF xxx available length of 3ft 6ft 15ft 25ft 50ft 75ft 100ft 150ft 200ft 250ft ö öIndicates super high resolution cable type TROUBLESHOOTING GUIDE 10 The TNP100UK supplied unit was carefully tested and no problems were detected however we would like to offer the following suggestions If there is no power check to see if ...

Page 13: ... important to ALTINEX that you receive all products that you have ordered and that this product meets your expectations In the unlikely event that an ALTINEX product needs to be returned please follow the policies below ALTINEX will accept all product returns for a period of 30 days from authorized ALTINEX dealers in an unopened package If a product has been opened the restocking fees will apply F...