TAEC Solar Box
Owner’s Manual
v2.2
14
Code
Connectors
Device
Characteristics
In
p
u
ts
S1
S1
Water Probe
Sensor NTC10K@25
o
C
Functioning temperature 0/120
o
C
Range 0/99
o
C
LP
LP
Low Pressure Contact Open / Closed
HP
11
High Pressure
Contact
Contact Open / Closed
12
3
N
Pump
Power 230v AC
Max 3A 230v AC
4
FON
Ou
tp
u
ts
5
N
Electrical
Heater
Power 230v AC
Max 3A 230v AC
6
FOFF
7
FON
8
COM
Compressor
Free contact
Max 8A 230v AC
9
N.C.
10
N.O.
Line
1
F
Input Line
230v AC +or- 10% 50 Hz;
Protection Fuse T3, 15 A
2
N
Absorbed Power
2 VA
Applied rules
EN 60730-1 50081-1 EN 60730-1 A1 50081-2
Outputs Test:
•
Enter in Installer Menu and scroll until the code T0
•
Press the K1 button to enter in the Test
•
Press the K1 button to activate the Heater corresponding LED ON display show tSt
•
Press the K2 button to activate the Compressor corresponding LED ON display
show tSt
•
Press K3 button to activate the Pump corresponding LED ON display show tSt
The selected output will be activated when you release the button Exit from MENU
•
Wait about 5 seconds
NOTE: REL (electric immersion heater) is not included on the equipment. It is the responsibility
of the installer to make its installation.
4.1.
Input /Output specifications