ADDITIONAL SPECIFICATIONS
Pressure Drop
Pressure Drop (Line Loss) within the boiler is
less than the pipe rating of the pipe within the
boiler, so there is no appreciable pressure drop.
Explanation of GPM Flow
The following are given as examples of gallons
per minute water flow required to deliver hot
water in order to provide heating of a given
number of degrees and at a certain BTU level:
500K BTU’s at 20 degrees temperature
differential requires 50 gallons per minute.
250K BTU’s at 20 degrees temperature
differential requires 25 gallons per minute
1M BTU’s at 20 degrees temperature
differential requires 100 gallons per minute