Logical Interface Number
PHY Instance, Interface, or PLL
12-15
Instance 1, TX PLL. The Fitter assigns all 4 logical TX PLLs to a
single physical PLL.
One PHY IP Core Instance with Eight Bonded Channels
This section describes logical channel numbering for one transceiver instance with eight bonded channels.
This example requires the Quartus II Fitter to place channels in two, contiguous transceiver banks. To
preserve flexibility for the Fitter, each channel and TX PLL is numbered separately. During place and
route, the Fitter maps the eight logical TX PLLs to a single physical TX PLL.
The following table illustrates the logical channel numbering. In this table, logical address 0 accesses data
channel 0 and logical address 8 accesses the TX PLL for data channel 0; logical address 1 accesses data
channel 1 and logical address 9 accesses the TX PLL for data channel 1, and so on. In simulation, to
reconfigure the TX PLL for channel 0, specify logical address 8 in the Streamer module’s
logical
channel number
. The Streamer module maps the logical channel to the physical channel which would be
the same value for all eight channels.
Table 16-30: Initial Number of Eight Bonded Channels
Channel
Logical Channel Number
Channel 0
0
Channel 1
1
Channel 2
2
Channel 3
3
Channel 4
4
Channel 5
5
Channel 6
6
Channel 7
7
CMU 0
8
CMU 1
9
CMU 2
10
CMU 3
11
CMU 4
12
CMU 5
13
CMU 6
14
CMU 7
15
16-54
One PHY IP Core Instance with Eight Bonded Channels
UG-01080
2015.01.19
Altera Corporation
Transceiver Reconfiguration Controller IP Core Overview