The Cyclone V Transceiver Native PHY IP Core provides direct access to all control and status signals of
the transceiver channels. Unlike other PHY IP Cores, the Native PHY IP Core does not include an Avalon
Memory-Mapped (Avalon-MM) interface. Instead, it exposes all signals directly as ports. The Cyclone V
Transceiver Native PHY IP Core includes the Standard PCS. You can select the PCS functions and control
and status port that your transceiver PHY requires.
The Native Transceiver PHY does not include an embedded reset controller. You can either design
custom reset logic or incorporate Altera’s “Transceiver PHY Reset Controller IP Core” to implement reset
functionality.
As the following figure illustrates, TX PLL and clock data recovery (CDR) reference clocks from the pins
of the device are input to the PLL module and CDR logic. The Standard PCS drives TX parallel data and
receives RX parallel data.
Figure 15-1: Cyclone Native Transceiver PHY IP Core
PLLs
PMA
altera _xcvr_native_cv
Transceiver Native PHY
RX PCS Parallel Data
TX PCS Parallel Data
CDR Reference Clock
TX PLL Reference Clock
CDR
RX Serial Data
to
FPGA fabric
Transceiver
Reconfiguration
Controller
Reconfiguration to XCVR
Reconfiguration from XCVR
TX and RX Resets
Calilbration Busy
PLL and RX Locked
Transceiver
PHY Reset
Controller
TX Serial Data
Serializer
De-
Serializer
Standard
PCS
©
2015 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are
trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as
trademarks or service marks are the property of their respective holders as described at
www.altera.com/common/legal.html
. Altera warrants performance
of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any
products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,
product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device
specifications before relying on any published information and before placing orders for products or services.
ISO
9001:2008
Registered
www.altera.com
101 Innovation Drive, San Jose, CA 95134