![Altera Cyclone IV Device Handbook Download Page 195](http://html1.mh-extra.com/html/altera/cyclone-iv/cyclone-iv_device-handbook_2910785195.webp)
Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices
8–31
Configuration
May 2013
Altera Corporation
Programming Parallel Flash Memories
Supported parallel flash memories are external non-volatile configuration devices.
They are industry standard microprocessor flash memories. For more information
about the supported families for the commodity parallel flash, refer to
Cyclone IV E devices in a single- or multiple-device chain support in-system
programming of a parallel flash using the JTAG interface with the flash loader
megafunction. The board intelligent host or download cable uses the four JTAG pins
on Cyclone IV E devices to program the parallel flash in system, even if the host or
download cable cannot access the configuration pins of the parallel flash.
f
For more information about using the JTAG pins on Cyclone IV E devices to program
the parallel flash in-system, refer to
AN 478: Using FPGA-Based Parallel Flash Loader
(PFL) with the Quartus II Software
In the AP configuration scheme, the default configuration boot address is 0×010000
when represented in 16-bit word addressing in the supported parallel flash memory
(
). In the Quartus II software, the default configuration boot address is
0×020000 because it is represented in 8-bit byte addressing. Cyclone IV E devices
configure from word address 0×010000, which is equivalent to byte address 0×020000.
1
The Quartus II software uses byte addressing for the default configuration boot
address. You must set the start address field to
0×020000
.
Summary of Contents for Cyclone IV
Page 10: ...x Chapter Revision Dates Cyclone IV Device Handbook March 2016 Altera Corporation Volume 1...
Page 14: ...I 2 Section I Device Core Cyclone IV Device Handbook March 2016 Altera Corporation Volume 1...
Page 274: ...vi Contents Cyclone IV Device Handbook February 2015 Altera Corporation Volume 2...
Page 440: ...iv Contents Cyclone IV Device Handbook December 2016 Altera Corporation Volume 3...
Page 442: ...vi Chapter Revision Dates Cyclone IV Device Handbook December 2016 Altera Corporation Volume 3...
Page 446: ......