Installer Manual-Quick Guide
Always isolate the AC Mains supply before installing or working on any components
that require 230 VAC 50Hz supply.
Introduction
A programmable controller is used to switch the heating system and/or
the hot water in your home on and off as needed. It works by controlling
the central heating and/or the hot water with programmed settings that
take effect at different times of the day.
Product Compliance
EU Directives: 2014/30/EU, 2014/35/EU and 2011/65/EU. Please check
www.saluslegal.com for the full information.
Safety Information
Use in accordance with the EU and national regulations.
For indoor use only.
Keep your device completely dry.
This product must be installed by a competent person and in accordance
with all the EU and national regulations.
Difference between ALTHC023/ALTHC024/ALTHC025
Installation
Jumper Settings
First Power Up
Button Function
The three models will offer you the possibility to customize your central heating
system and hot water system as desired.
ALTHC023 is recommended for users that want to control only the Central Heating
or the Hot Water system.
ALTHC024 is designed to give you a full control with only one device of both your
Central Heating and Hot Water system.
ALTHC025 is the most versatile product of this line and lets you manage two
different Central Heating zones and the Hot Water with only one controller.
Model: ALTHC023/ALTHC024/ALTHC025
Input: 230V, 50Hz
Output: 3A/ switch terminal
1
2
3
ALTHC023
Volt Free application only
ALTHC024
- 230V Application
ALTHC025
- 230V Application
ALTHC023
- 230V Application only
Note
: Please remove red link wire for this application.
Terminal
Description
Backplate
N
Mains Neutral
L
Mains Live
1
Not Used
2
Not Used
3
Volt Free Connection
4
Volt Free Connection
Earth Parking
(no electrical connection)
N L 1 2 3 4
N L 1 2 3 4 5 6
Terminal
Description
Backplate
N
Mains Neutral
L
Mains Live
1
NC (Output)
2
Not Used
3
Switch Live (Output)
4
230V Common (via Link)
Earth Parking
(no electrical connection)
N L 1 2 3 4
N L 1 2 3 4 5 6
Terminal
Description
Backplate
N
Mains Neutral
L
Mains Live
1
Hot Water Off
2
Central Heating Off
3
Hot Water On
4
Central Heating On
Earth Parking
(no electrical connection)
N L 1 2 3 4
N L 1 2 3 4 5 6
Terminal
Description
Backplate
N
Mains Neutral
L
Mains Live
1
Hot Water Off
2
Central Heating Off
3
Hot Water On
4
Central Heating 1 On
5
Central Heating 2 On
6
Central Heating 2 Off
Earth Parking
(no electrical connection)
N L 1 2 3 4
N L 1 2 3 4 5 6
Changes to the jumpers settings should only be made by the Engineer carrying
out the installation or other qualified person. The installer should select the jumper
positions required if changes need to be made to the factory default settings.
These jumpers are found on the rear of the controller.
* P - Fully pumped system for independent Central Heating and Hot Water.
* G - Gravity Hot Water system with Pumped Central Heating.
ALTHC023/ ALTHC024/ ALTHC025
Switching Bridges
Switch
Program
5-2 days programme or
24h programme
Fully pumped system(P*)
or gravity-fed hot water
system(G*)
Disable/enable the internal
backup battery
System
Feature
ALTHC023
/
025
Settings
Memory
Backup
5-2
24H
24H
5-2
NA
NA
P
G
OFF
ON
OFF
ON
ALTHC024
Settings
ALTHC023/ALTHC025
ALTHC024
ALTHC023
ALTHC025
ALTHC024
1. Turn on the LCD backlight
2. Press for 3 sec to activate Holiday mode
Select operating mode (ON, ONCE, AUTO, ADV, OFF)
Activate/deactivate Boost function
Decreases the selected setting
Increases the selected setting
Select a clock or programme setting
Sets a clock or programme setting
Reset to Factory settings
ALTHC023
CH or HW
ALTHC024
CH and HW
ALTHC025
2x CH and 1x HW
MODE
SELECT
SET
+HR