Altec AIR, LLC
P210WLP Series Air Dryer User’s Guide
Page 65 of 96
P017455 – Rev. N
9.9.2
Depressurize air Dryer (
See sections 11.1 for detail).
This prevents the compressor from shutting down.
When the compressor runs for 5:00 minutes (unless adjusted to a different
Set Point by the user), a High Compressor Last Run Time (
LAST RUN
)
alarm should appear on the System Screen.
9.9.3
Press the
RESET Button
to clear the
alarm.
If you are unable to create a High
Compressor Last Run Time alarm as
described, see section 13.18 for
troubleshooting information.
9.10 Testing Humidity Alarm and System Shutdown
CAUTION
: Be careful when removing Air hose. System is pressurized.