Altec AIR, LLC
P210WLP Series Air Dryer User’s Guide
Page 61 of 96
P017455 – Rev. N
If the incoming voltage measures less than indicated above, it is recommended
that steps be taken at your facility to increase the power to the recommended level
of voltage.
9.5 Testing Consistent Heatless Dryer Cycling
With the Compressor running
:
9.5.1
Locate the purge port on
the rear of the unit
Place your hand behind the purge port to feel for purging air. Air should
be steadily purging from the port, and a burst of air should be felt every 60
seconds as the dryer cycles between towers.
If the Heatless Dryer is not cycling consistently as described, see section 13.13
for troubleshooting information.
WARNING!
Internal surfaces may be hot
. Use care when coming into contact
with internal components as there is a potential for some of these
components to become hot when in operation or standby.