8.9 Setting the System Pressure
With Compressor running:
8.9.1
Open Panel (see section 8.8 ).
8.9.2
Pull the Capacity Control Valve knob
out.
8.9.3
Turn the knob until the reading on the
Pressure Gauge is
50 PSI
.
8.9.4
Push the knob in to lock.
8.9.5
Close Panel.
8.10 Setting the Outlet Pressure
8.10.1
Locate the outlet pressure regulator on the front of the unit
8.10.2
Turn knob until Outlet
Pressure (
OUTP
)
reading is at the desired
setting.
8.10.3
Tighten the retaining
nut to lock value in
place.
8.11 Connecting to Common Alarm Terminals