5.

 

Regulatory Compliance

 

5.1.1.

 

FCC  

Please notice that if the FCC identification number is not visible when the module 
is  installed  inside  another  device,  then  the  outside  of  the  device  into  which  the 
module is installed must also display a label referring to the enclosed module. This 

exterior  label  can  use  wording  such  as  the  following:  “Contains  FCC  ID: 

2AN5Z-

001R1

” any similar wording that expresses the same meaning may be used.

 

 
Manual Information to the End User:

 

1.

 

The ALT1210MOD-VZ-01 module is limited to OEM installation ONLY. 

2.

 

The OEM integrator should provide a user manual that should clearly indicate 
the operating requirements and user guidelines.  

3.

 

The  OEM  is  responsible  for  ensuring  that  the  end-user  has  no  manual 
instruction to remove or install the module. 

4.

 

This device complies with FCC radiation exposure limits set forth for an 
uncontrolled environment and it should be installed and operated with a 
minimum distance of 5.3 cm between the radiator and an extremity (such as 
an arm) or 7.9 cm between the radiator and the body.  If an end product 
incorporates this module in a configuration where it would be closer to an 
extremity or the body (a portable/wearable device) then SAR testing would be 
required.  The integrator is responsible for ensuring compliance in the host, 
which could involve power reduction control. 

5.

 

This  transmitter  module  has  not  been  evaluated  for  simultaneous  operation 
with  other  transmitters.  In  a  multi-transmitter  integration  scenario,  an 
evaluation  must  be  performed  to  ensure  RF  Exposure  compliance.  The 
integrator is responsible for ensuring compliance in the host. 

5.1.2.

 

GCF 

This device complies with the 3GPP Rel 9 specification. 

5.1.3.

 

Verizon wireless conformance 

This device complies with Verizon Wireless conformance 

 

Summary of Contents for ALT1210MOD-VZ-01

Page 1: ...THE WORLD S LTE LEADER 6 Ha harash Street P O Box 7158 Hod Hasharon 45240 ISRAEL Tel 972 74 780 0800 Fax 972 9 740 3049 ALT1210MOD VZ 01 User Module Jan 2018...

Page 2: ...which Altair products or services are used Information published by Altair regarding third party products or services does not constitute a license from Altair to use such products or services or a w...

Page 3: ...or Proprietary and Confidential 3 Document Revision Control Edition Issued By Date Description 0 1 Alon K 17 12 2017 Initial specification 0 2 Alon K 11 01 2018 Minor modifications and additions 1 0 A...

Page 4: ...12 4 1 5 General Power Related Guidelines 14 4 2 Power up and Power Down Sequences 15 4 3 Specific Interfaces Guidelines 15 4 3 1 RF Pin 36 15 4 3 2 Host Interface Pins 27 and 79 16 4 3 3 UIM Interfa...

Page 5: ...ALT1210MOD VZ 01 User Module Rev 1 0 Altair Semiconductor Proprietary and Confidential 5 5 1 2 GCF 18 5 1 3 Verizon wireless conformance 18...

Page 6: ...User Module Rev 1 0 Altair Semiconductor Proprietary and Confidential 6 1 Scope The purpose of this document is to be used as a basic user manual for designers developing products based on the ALT1210...

Page 7: ...requiring real time communication along with long battery life 2 1 General Features Frequency range B4 UL 1710 1755MHz DL 2110 2155MHz B13 UL 777 787MHz DL 746 756MHz LTE Category Category 1 SW upgra...

Page 8: ...lectrical Specification Item Min Typ Max Units Notes Required Power Supplies Rating VBAT 3 2 3 8 4 3 V If USB interface is not used the Vin voltage can be further reduced up to 3 0V IVBAT 400 mA VPA 3...

Page 9: ...miconductor Proprietary and Confidential 9 3 Pinout 3 1 Land Pattern Module size 15 X 15 mm Pad size o Signal pin 0 7 X 0 5 mm o Thermal pin 1 0 X 1 0 mm Pitch o same loop 0 8 mm o 1st to 2nd loop 1 0...

Page 10: ...GND FEM_CTRL5 FEM_CTRL2 FEM_CTRL3 FEM_CTRL6 FEM_CTRL7 FEM_CTRL4 GND SAR_VAINP2 GND FEM_CTRL1 GND GND GND GND GND GND VPA GND PCM_SYNC SPIM_CLK SPIM_EN_1 GND GND GND 1 2 VBAT VBAT VBAT 9 VDD_RET_IN 3...

Page 11: ...out signal SF_nWP IO2 Serial flash write protect signal SF_nHOLD IO3 Serial flash HOLD signal SF_nCS1 Serial flash chips select signal SPI_M_CLK SPI master interface clock signal SPI_M_MOSI SPI master...

Page 12: ...mize BOM cost or size at the expense of power consumption it is possible to supply this rail directly from the battery Host needs to disable the Modem when the battery voltage drops towards 3 0V In ap...

Page 13: ...vel The second option is using an external supply The motivation is to allow shutting down additional circuits inside the Module in order to achieve an even lower floor power consumption in lite hiber...

Page 14: ...70 FEM_CTRL2 31 Host GPIO1 1 8V For IOs and DDR DC DC 3 0V For RF PAs GPIO2 En Vout Vin DC DC En Vout Vin DC DC En Vout Vin 3 2V Main supply RETLE_N_OUT RETLE_N_IN FEM_CTRL0 21 76 22 VO18R_OUT 62 It r...

Page 15: ...e stable before the shutdown pin is set low and the system boots up The proper power down sequence would be the opposite Shutdown pin is set high shutting the modem internal supplies and modem VPA shu...

Page 16: ...rs to maintain the polarity of the SIM_CLK line for eSIM devices Regular SIM devices may be used externally to the module but since all modem digital IOs are not maintained during hibernation states i...

Page 17: ...Z 01 has 4 ADC converters to measure external signals The readings can be done by AT command or from the application layer 4 3 10 SPI Master Pins 107 108 54 55 and 63 This is a 4 wire bus with two chi...

Page 18: ...on to remove or install the module 4 This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it should be installed and operated with a minimum distance o...

Reviews: