Chapter 3
– Hardware Design
RPV311
RPV311-TM-EN-6
51
D
Up to 8 pairs of connectors for fiber-optic links. For each link there is an Act indicator that lights up when
the link is receiving data of the acquisition module.
E
AC or DC power input.
F
4 dry contact relays.
G
Electrical and Optical (optional) IRIG-B input for the external synchronization of the equipment.
H
2 electrical Ethernet interfaces for the communication between the equipment.
I
1 electrical Ethernet interface for the Process Bus communication.
J
Double internal converter for optical Ethernet interface.
K
Serial port RS323 for modem connection.
L
Maintenance ports for exclusive use by Alstom's technical support personnel.
3.2
RA331
3.2.1
MAIN FEATURES
Up to 8 analog inputs (voltage, current, DC transducers, probes);
Up to 32 digital inputs;
16-bit analog-to-digital converters, 256 points-per-cycle sampling rate;
Frequency response of DC to 3.0 kHz;
Fiber-optic interface to connect to the processing module;
Up to 2 km fiber-optic links;
Front panel mounting or internal panel mounting.
3.2.2
COMPONENTS
shows all the components of the RA331 module.
Summary of Contents for Reason RPV311
Page 2: ......
Page 15: ...INTRODUCTION CHAPTER 1...
Page 34: ...SAFETY INFORMATION CHAPTER 2...
Page 45: ...HARDWARE DESIGN CHAPTER 3...
Page 56: ......
Page 57: ...CONFIGURATION CHAPTER 4...
Page 75: ...RPV311 Chapter 4 Configuration RPV311 TM EN 6 75 Figure 21 Email Fax configuration...
Page 77: ...RPV311 Chapter 4 Configuration RPV311 TM EN 6 77 Figure 22 Adding and editing voltage circuits...
Page 117: ...OPERATION CHAPTER 5...
Page 121: ...RPV311 Chapter 5 Operation RPV311 TM EN 6 121 Figure 46 Status monitoring sequence...
Page 123: ...RPV311 Chapter 5 Operation RPV311 TM EN 6 123 Figure 47 Monitoring sequence...
Page 128: ...Chapter 5 Operation RPV311 128 RPV311 TM EN 6 Figure 50 Equipment settings monitoring sequence...
Page 155: ...RECORDS CHAPTER 6...
Page 172: ......
Page 173: ...TW FAULT LOCATOR CHAPTER 7...
Page 183: ...PMU CHAPTER 8...
Page 189: ...MODBUS CHAPTER 9...
Page 193: ...DNP3 CHAPTER 10...
Page 196: ......
Page 197: ...GOOSE MESSAGE DETECTION CHAPTER 11...
Page 200: ......
Page 201: ...SOFTWARE RPV TOOLS CHAPTER 12...
Page 228: ......
Page 229: ...SOFTWARE RPV MANAGER CHAPTER 13...
Page 249: ...COMMUNICATIONS CHAPTER 14...
Page 261: ...INSTALLATION CHAPTER 15...
Page 295: ...Chapter 15 Installation RPV311 RPV311 TM EN 6 295 Figure 138 RA331 RA332 and RA333 dimensions...
Page 299: ...MAINTENANCE AND TROUBLESHOOTING CHAPTER 16...
Page 310: ...TECHNICAL SPECIFICATIONS CHAPTER 17...
Page 331: ...RPV311 Chapter 17 Wiring Diagrams WIRING DIAGRAMS CHAPTER 18...
Page 340: ...APPENDIX A...