M3x5/EN M/B
User Manual
Page 24
iSTAT M3x5
FIGURE 8-11: RS232/RS485 CONNECTIONS
A second RS232/RS485 port (COM2) may also be available depending on which RTC
synchronization method is used (see section 8.9).
8.6.2
Ethernet Communications
The
M3x5
can be supplied with an Ethernet port, which is always supplied alongside an USB
port. This option will have a rear mounted RJ45 Ethernet connecter, along with an USB
connector.
Both of the Ethernet and USB ports can be used simultaneously allowing interrogation locally
and remotely at the same time.
Note that each
M3x5
will have a unique MAC number indicated on the label that can be used
when configuring for Ethernet communications.
FIGURE 8-12: ETHERNET/USB
8.6.3
USB Communications
The
M3x5
can be supplied with a USB port, via a rear mounted USB type B connector.
USB communication serves as a fast peer-to-terminal data link. The instrument is detected
by the host as a USB 2.0 compatible device.
If both Ethernet and USB ports are fitted they can be used simultaneously allowing
interrogation locally and remotely at the same time.
FIGURE 8-13: USB
8.7
Inputs and Outputs – Main modules 1 & 2
The
M3x5
can be supplied with two main input/output modules, designated 1 & 2, situated
on the rear of the case. Each of these modules has 2 channels and can be factory
configured to one of the options shown in table 8-2: