KOSCIUSKO & STIRLING HEATER
INSTALLATION
SAFETY NOTICE
•
Please read this manual before you use or install your Alpine Heater.
•
If this Alpine Heater is not properly installed, it may result in a house fire. This Heater should
only be installed by a certified installer
. Makeshift methods or compromises in installation
may result in a safety hazard and void the warranty.
•
For your safety and protection always obtain council approval to install your Heater.
Your Alpine Heater installation must conform to Australia standard AS2918-1990. When installing
this appliance use only a flue kit which has been tested and approved to Australian Standard 2918.
Only use a 150 diameter flue pipe
–
an increase or decrease in the diameter of the flue can effect the
draft and can cause poor performance of the appliance. MINIMUM flue length is 3.6 meters.
Minimum Clearance to combustibles and hearth dimensions.
HEATERS
Stirling F/S
Stirling Insert
Kosciusko
Box
Facia
Width
690
605
895
770
Height
760
585
695
820
Depth
500
370
550
Rear Clearance
150
N/A
150
Side Clearance
375
N/A
350
Cnr Clearance
125
N/A
125
Note: Curtains and other flammable materials that may vary the above measurements, should be
considered, and located well clear of the appliance.
SAFETY WARNINGS
•
Do not use flammable liquids such as petrol, lantern fuel, kerosene, charcoal lighter fluid or
similar liquids to start or freshen up a fire. Always keep such liquids well clear of the
appliance.
•
Appliance surfaces become hot during use. Keep children away from appliance during
operation.
•
Only persons familiar with this heater should be allowed to operate.
•
DO NOT OVERFIRE this heater. Always operate with the door closed.