Enter the disarm and arm times using the numerical keys of the keypad. When you start entering the first
time (disarm time), and the first character is a “1”, the display will change to:
RTC 1 T1 OFF/ON:
Su 1_:__ / 00:00
Now enter the disarm and arm times for time block 1 (T1) . So, if the system is to be disarmed at 08.00
hours in the morning and arm at 18.00 hours at night, enter 08001800.
Any time between 00.01 and 23.59 hours can be entered. You can enter a time of 00.00 hours, but the
control panel will ignore this. So, if the times 00.00 / 18.00 are entered, the control panel will ignore the
disarm time at 00.00 hours (so it will not disarm) and will only arm (if possible) at 18.00 hours.
When an invalid time is entered, the following message will appear on the LCD display:
Entered time
incorrect! <#>
Press the <#> key and enter a valid time.
When for both time fields valid times are entered, press the <#> to confirm the choices and to proceed with
the second time block (T2). The display will change to:
RTC 1 T2 OFF/ON:
Su 00:00 / 00:00
Now the disarm and arm times for the second time block T2 can be entered. Enter the times in the same way
as for time block T1. If there is no need to program a second time block, press the <#> key to keep the times
00.00/00.00 unchanged and to proceed with the next day. The display will change to the first time block T1
of the next day:
RTC 1 T1 OFF/ON:
Mo 00:00 / 00:00
Repeat this procedure for each day of the week, for each time block (T1 and T2), and for all disarm- and arm
times. Use the <
↑
> and the <
↓
> keys to scroll up and down the times, time blocks and days.
Press the <*> key to return to the main menu. From here the next timer switch (RTC) can be programmed.
F24# Program overtime
The AlphaVision NG control panel has an overtime function. With the overtime function the next arm time
can be delayed. This is used in situations were people work overtime and want to delay the next arming
time. The delay of the next arm time is entered for each timer switch separately and is only valid for the next
arm time, after this, the timer switch functions as usual again. To delay the arm time of a timer switch,
function 24 can be used.
Press <?> <2> <4> <#>, followed by a level 3, 4 or 5 user code.
The following message will appear on the display:
Enter number of
RTC module: .
Enter the number of the timer switch (1-4 ) of which the arm time should be delayed, followed by the <#> to
confirm.
AlphaVision NG installation manual Rev. 2.0 27-08-2003 Blz. 80/101
When the number of the timer switch has been entered, the display will change to: