![alphatronics AlphaCom XL Service Manual Download Page 72](http://html.mh-extra.com/html/alphatronics/alphacom-xl/alphacom-xl_service-manual_2906562072.webp)
Service manual AlphaCom XL transceiver Rev. 1.4 10-08-2011
Blz. 72/74
APPENDIX G: SIA-codes
For certain functions and programming options it is possible to program a SIA / SIA-HS code. The codes
used are usually determined together with the central station. In the table below you will find a list of the
most commonly used codes.
SIA code
Definition
Description
AR
AC Restore
(230V restore)
AT
AC Trouble
(230V failure)
BA
Burglary Alarm
BR
Burglary Restoral
OP
Opening
(Disarming message)
CI
Automatic Closing Failed
(Attempt to automatically arm has failed).
Also used if the system has been „disarmed to long‟‟ when a partition containing a
„safe detector‟ has been disarmed longer than the time programmed.
CJ
Late Close
(Restoral of partition that was disarmed to long)
CL
Closing
(Arming)
DR
Duress
(Disarming under threat)
FA
Fire Alarm
FR
Fire Restoral
HA
Holdup Alarm
HR
Holdup Restoral
MA
Medical Alarm
MR
Medical Restoral
OP
Opening
(Disarming)
RP
Test message
RR
Reset
(Start-up message of the system)
TA
Tamper Alarm
TR
Tamper Restoral
UA
Undefined Alarm
(Technical alarm)
UR
Undefined Restoral
(Restore message of Technical alarm or tamper)
XJ
Xmitter Supervision Restoral
(Restore of supervision message of a wireless detector)
XR
Xmitter Restoral
(Restore of low-battery message of a wireless detector)
XS
Xmitter Supervision
(Supervision alarm of a wireless detector)
XT
Xmitter Trouble
(Low-battery message of a wireless detector)
YR
Battery Restoral
(Restore of low-battery control panel)
YT
Battery Trouble
(Low-battery control panel)