background image

 

 
 

Heatmaster 2

 

fan speed signal from only one fan can be monitored, but the other fans run at the same voltage. Such a 
configuration is especially useful if many fans need to be connected to a cooling array. For example, three 
radiator fans can be connected to one channel. Bundling of radiator fans also comes in very handy if large 
radiators such as the Mora or Phobya Nova (9 fans each). The maximum permissible number of connected 
fans depends on the power consumption of the fans. Up to 18W of power may be drawn from an individual 
channel passiv cooled..We propose to use an aktiv fan. The power consumption of a standard 120mm fan is 
approximately 2.5 to 3.6W. Before connecting multiple fans please check the maximum power draw of the 
fans. Should the 10W per channel not suffice, an active cooling system of the driver components can 
increase the maximum power output up to 38W. Regarding this please consult the appendix.  
 
The last three channels (3-Pin) are unregulated for the pumps / flow sensors, as these are controlled 
separately by the software. Theoretically it is also possible to connect a fan, but the channels are unable to 
detect it as such, resulting in constant 12V operation of the connected fan. The 3 channels for pumps / flow 
sensors aren’t necessarily compatible with the according components. This means that in some cases it is 
e.g. necessary to connect a 3-Pin plug to the pump / flow sensor. Please check in advance if the pump is 
suitable for the limitations of the Alphacool Heatmaster 2 (18W per channel). On the 3 channels the 12V DC 
voltage from the PSU is simply passed through, hence additional voltage adjustments are not possible. If you 
wish to control the speed of your pump, this is possible with an analogue adaptor which is connected parallel 
to the 6 fan channels. This allows a pump to be connected and controlled in speed e.g. according to a 
measured temperature. Such analogue adaptors will be available soon. The following products can be 
connected to the pump / flow sensor channels: 
 

Pumps 

 

EK-DCP 2,2 /4,0 

 

Laing DDC-1T / Laing DDC-1T Plus ( requires active cooling)  (as well as the RT models) 

 

Laing DDC-1T Plus (RT-Models) (Active Air cooling needed) 

 

Laing D4/ Laing D5 (Active cooling needed) 

 

Alphacool TPP644 / VPP655 ((Active cooling needed) 

 

Phobya DC12-220/260/400 

Please note that the Alphacool pump adaptor may be needed for some models! 

Flow rate sensors 

 

Bach DFS 1/25io 

 

Some Digmesa DF sensors 

 

GMR DF Sensor including electronics 

 

Innovatek FlowMeter  

Regarding different pumps respectively the precise connection possibilities please consult our website 

www.alphacool.com

. 

Connection array 

 

USB 

Connector for the USB cable. 

Summary of Contents for Heatmaster 2

Page 1: ...Alphacool International GmbH Heatmaster 2 Operating Manual...

Page 2: ...ation reserved Analog and digital reproduction of any kind except a copy of the end user customer requires the written permission of the Alphacool International Gmbh This manual is written according t...

Page 3: ..._________________________________________________________ 9 PC shut down ________________________________________________________________________ 9 NTC 1 6 temperature sensors ________________________...

Page 4: ...___ 18 Settings____________________________________________________________________________ 18 Temperature values __________________________________________________________________ 19 Pump flow rate s...

Page 5: ..._______________________________________________23 TECHNICAL DATA _____________________________________________________23 DISPOSAL ____________________________________________________________23 APPENDI...

Page 6: ...correctness of this data Regarding the type and extent of the order only the information provided with the order and order confirmation are determining 1 If a defect covered by the warranty occurs yo...

Page 7: ...alled solidly in a free space in the enclosure Please make sure that the USB connector is connected with the correct polarity If the USB cable is connected with wrong polarity both the Mainboard as we...

Page 8: ...age www Alphacool com Socket assignment Overview Power supply The Alphacool Heatmaster 2 is connected to the power supply via a 4 Pin Molex plug just like a HDD or optical drive Both voltage 12V and 5...

Page 9: ...nels for pumps flow sensors aren t necessarily compatible with the according components This means that in some cases it is e g necessary to connect a 3 Pin plug to the pump flow sensor Please check i...

Page 10: ...2 detects these after a reset The setting can also be made manually Water level To this input an analogue coolant level sensor can be connected With this sensor the Heatmaster is able to give a warnin...

Page 11: ...rity may lead to destruction of the Mainboard and or the Alphacool Heatmaster 2 Now connect the power cable 4 Pin plug Be very careful not to damage the other components on the board Now connect the c...

Page 12: ...d with the installation Choose the target folder for the installation Click on Install to proceed Setup_USB will copy the required files For the connection between PC and Alphacool Heatmaster 2 a spec...

Page 13: ...ditions to proceed with the installation Click on Next to proceed Choose the target folder for the installation of the USB driver Click on Next to proceed Click on Install to proceed with the installa...

Page 14: ...ck on Install to implement the hardware The setup will search for connected devices Confirm by clicking OK to complete the installation The driver installation is now complete Click on Finish to close...

Page 15: ...s been installed the software can be installed To start the software setup open the file Setup_HM2 Choose the desired language The installation assistant will start Click on Next to proceed Accept the...

Page 16: ...r 2 software Click on Next to proceed Choose a start menu folder Click on Install to proceed The Heatmaster 2 software is now being installed All settings are now made and the Heatmaster 2 software ha...

Page 17: ...atmaster 2 This is especially important if multiple devices are connected e g in a server or network Temperature unit The temperature can be displayed in C or K The setting made here will be automatic...

Page 18: ...et Fan configuration Here the fan channel for which the settings will be made can be Name It is possible to name every fan channel individually The name may contain up to 255 characters made up of let...

Page 19: ...ible for the Alphacool Heatmaster 2 to maintain the set target temperature This is not an error or reason for reclamation but rather caused by the many possible settings of the Heatmaster 2 as well as...

Page 20: ...to Off not connected or On Type Here the channel can be set to pump or flow rate sensor mode Factor This factor represents how many signals the pump flow rate sensor sends per revolution Normal flow...

Page 21: ...determine the conversion factor for the water level in percent Online button relay configuration The online relay and button control allows highly complex adjustments to be made whilst the system is r...

Page 22: ...stem The only requirement is an active stand by power supply as well as buttons and relays which will be available as accessories soon Please note that we have refrained from disabling settings which...

Page 23: ...nteed that your system will always be protected Especially the automatic reboot feature on some Mainboards may lead to complications with the relay button configuration This greatly depends on the Mai...

Page 24: ...m x 145mm Current draw max 6 3A Fan channel output power max 18W 38w aktiv cooled per channel Overall maximum output power max 75W overall Maximum relay channel power consumption max 5W per relay Disp...

Page 25: ...tion in the world Expansion for analogue adaptor For special fans e g in the laboratory sector it is possible to connect an analogue expansion strip parallel to the existing fan channels This expansio...