ALWAYS ensure correct connection to the pins! If incorrect connections are made or pins are 
shorted out, damage may be caused to the Alphacool Heatmaster and / or the connected hardware. 
Pay special attention to the correct connection of the USB cable. If the cable is connected improperly 
damage may be caused to the Alphacool Heatmaster 2 or the connected hardware. Never remove the 
USB connection cable when the system is switched on. The Heatmaster 2 is not hot-plug capable. 
 

HM BUS 

Heatmaster 2 BUS-utilization inquiry. 
 

Emergency shutdown 

Output for switching of a relay. Via this feature the hardware can be switched off immediately in case of an 
emergency.  The  switching  current  must  not  exceed  100mA. 

Data  corruption  cannot  be  ruled  out  if  the 

emergency shutdown is activated. 

 

 

PC shut down  

This output can be connected to the Mainboard. When the shut-down signal is sent, the output works like the 
power switch of the system. 
 

NTC 1 -6 temperature sensors 

Here the temperature sensors can be connected. Use only sensors with a resistance of 5k Ohm or 10k Oh. 
The Heatmaster 2 detects these after a reset. The setting can also be made manually. 
 

Water level 

To this input an analogue coolant level sensor can be connected. With this sensor the Heatmaster is able to 
give a warning if the coolant level is too low. 
 

LED 1 silent alarm 

Status LED. This connector is active when the silent alarm is activated. The switching current must not 
exceed 2mA. 
 

LED 2 alarm 

Status LED. Is active when the alarm is activated. The switching current must not exceed 2mA. 
 

LED 3 warning 

Status LED. Is active when a warning is activated. The switching current must not exceed 2mA. 
 

Relay 1-3 

With the outputs relays can be controlled, the switching current must not exceed 80mA. 
 

Button 1-3 

Inputs for 3 buttons. The buttons must be equipped with a make contact to allow the Heatmaster 2 to 
interpret the signal correctly. 
 

Heatmaster reset 

With the Jumper the Heatmaster can be restarted. To restart remove the jumper for a short period of time 
and plug it in again. 
 

When conducting a hardware reset it is necessary to disconnect the Heatmaster 2 in the software if 
the software is started.  

 

IMPORTANT: A reset switches off all outputs!

 

 

5V Standby 

Power supply for stand-by operation. The PSU must be able to supply at least 1A of current at 5V. 
 

12V and 5V output 

Power supply for external devices. 

 

 

Summary of Contents for Heatmaster 2

Page 1: ...Alphacool International GmbH Heatmaster 2 Operating Manual...

Page 2: ...ation reserved Analog and digital reproduction of any kind except a copy of the end user customer requires the written permission of the Alphacool International Gmbh This manual is written according t...

Page 3: ..._________________________________________________________ 9 PC shut down ________________________________________________________________________ 9 NTC 1 6 temperature sensors ________________________...

Page 4: ...___ 18 Settings____________________________________________________________________________ 18 Temperature values __________________________________________________________________ 19 Pump flow rate s...

Page 5: ..._______________________________________________23 TECHNICAL DATA _____________________________________________________23 DISPOSAL ____________________________________________________________23 APPENDI...

Page 6: ...correctness of this data Regarding the type and extent of the order only the information provided with the order and order confirmation are determining 1 If a defect covered by the warranty occurs yo...

Page 7: ...alled solidly in a free space in the enclosure Please make sure that the USB connector is connected with the correct polarity If the USB cable is connected with wrong polarity both the Mainboard as we...

Page 8: ...age www Alphacool com Socket assignment Overview Power supply The Alphacool Heatmaster 2 is connected to the power supply via a 4 Pin Molex plug just like a HDD or optical drive Both voltage 12V and 5...

Page 9: ...nels for pumps flow sensors aren t necessarily compatible with the according components This means that in some cases it is e g necessary to connect a 3 Pin plug to the pump flow sensor Please check i...

Page 10: ...2 detects these after a reset The setting can also be made manually Water level To this input an analogue coolant level sensor can be connected With this sensor the Heatmaster is able to give a warnin...

Page 11: ...rity may lead to destruction of the Mainboard and or the Alphacool Heatmaster 2 Now connect the power cable 4 Pin plug Be very careful not to damage the other components on the board Now connect the c...

Page 12: ...d with the installation Choose the target folder for the installation Click on Install to proceed Setup_USB will copy the required files For the connection between PC and Alphacool Heatmaster 2 a spec...

Page 13: ...ditions to proceed with the installation Click on Next to proceed Choose the target folder for the installation of the USB driver Click on Next to proceed Click on Install to proceed with the installa...

Page 14: ...ck on Install to implement the hardware The setup will search for connected devices Confirm by clicking OK to complete the installation The driver installation is now complete Click on Finish to close...

Page 15: ...s been installed the software can be installed To start the software setup open the file Setup_HM2 Choose the desired language The installation assistant will start Click on Next to proceed Accept the...

Page 16: ...r 2 software Click on Next to proceed Choose a start menu folder Click on Install to proceed The Heatmaster 2 software is now being installed All settings are now made and the Heatmaster 2 software ha...

Page 17: ...atmaster 2 This is especially important if multiple devices are connected e g in a server or network Temperature unit The temperature can be displayed in C or K The setting made here will be automatic...

Page 18: ...et Fan configuration Here the fan channel for which the settings will be made can be Name It is possible to name every fan channel individually The name may contain up to 255 characters made up of let...

Page 19: ...ible for the Alphacool Heatmaster 2 to maintain the set target temperature This is not an error or reason for reclamation but rather caused by the many possible settings of the Heatmaster 2 as well as...

Page 20: ...to Off not connected or On Type Here the channel can be set to pump or flow rate sensor mode Factor This factor represents how many signals the pump flow rate sensor sends per revolution Normal flow...

Page 21: ...determine the conversion factor for the water level in percent Online button relay configuration The online relay and button control allows highly complex adjustments to be made whilst the system is r...

Page 22: ...stem The only requirement is an active stand by power supply as well as buttons and relays which will be available as accessories soon Please note that we have refrained from disabling settings which...

Page 23: ...nteed that your system will always be protected Especially the automatic reboot feature on some Mainboards may lead to complications with the relay button configuration This greatly depends on the Mai...

Page 24: ...m x 145mm Current draw max 6 3A Fan channel output power max 18W 38w aktiv cooled per channel Overall maximum output power max 75W overall Maximum relay channel power consumption max 5W per relay Disp...

Page 25: ...tion in the world Expansion for analogue adaptor For special fans e g in the laboratory sector it is possible to connect an analogue expansion strip parallel to the existing fan channels This expansio...

Reviews: