background image

Learning button

Wind adjust button

Wind threshold

Light adjust button

Light threshold

SUN & WIND SENSOR p1

ALPHA SUPPORT PHONE (909) 307-2320

Power: Ni-MH/3.6

olar Panel + Battery

V   S

Protectio

ndex: IP44

n I

Temperature: -20

to

+ 60

Working Current: ≤12mA
Codes:

Codes

Rolling

Frequency: 433.92MHz

Instruction guide for

R

Wind/Sun Sensor S001

1. TECHNICAL DATA

2. STRUCTURE

Wind cup

Base

Solar panel

RS-001

3. MOUNTING

It’s very important that the sensor be mounted so that the wind cups are as level as possible, as per the diagrams above. Failure to
do so may create friction that makes it harder for the cups to spin, thus affecting the performance and reliability of the device. Also
ensure that the device is mounted in an area that receives the same wind conditions as the awning if using wind sensing, and also
full sunlight during the day if using the sun sensing for control purposes. Make sure to test for connection between the device and

-

the motor once set up.

02. Installation chart

4. INSTALLATION POSITION

Fixing components

Screw

Summary of Contents for RS-001

Page 1: ...ery important that the sensor be mounted so that the wind cups are as level as possible as per the diagrams above Failure to do so may create friction that makes it harder for the cups to spin thus affecting the performance and reliability of the device Also ensure that the device is mounted in an area that receives the same wind conditions as the awning if using wind sensing and also full sunlight...

Page 2: ...rts to flash Then release Hold down the right button until the left LCD digit starts to flash Then release Press the STOP button 8 times The motor will vibrate after the 8th press Press the learning button on the motor twice Repeatedly press the left button to select a setting between 0 5 Repeatedly press the right button to select a setting between 0 9 Press the learning button on the motor twice T...

Page 3: ...bove 100 000 it will show 99 All other readings are simply multiplied x 1 000 Unit will time out after 3 minutes if untouched in that time 2 Control by light sensing Press LEFT button 4 times The dot in the middle is always on Check display for wind speed reading Press the RIGHT button to bring the unit out of testing mode Press RIGHT button 4 times The dot in the corner is always on Check display...

Page 4: ...e same button until the desired wind setting is displayed Tap the light setting button to exit the wind setup and the flashing will stop 0 Off 1 10 kmh 2 15 kmh 3 20 kmh 4 30 kmh 5 40 kmh 4 Setting the Light level Note it is not recommended to use the light control for folding arm awnings unless you want the awning out every day of the year including potentially when it is raining Light control is m...