C048-699-30 R03, Rev. B (01/2021)

Table 12. 

Battery Mounting Bracket Kits - For C&D Technologies

® 

Batteries

DESCRIPTION

APPLICABLE BATTERY SYSTEM

PART NUMBER

DCX Mount Kit, C&D MSE AT35

AT-27, AT-35

C016-372-10

DCX Mount Kit, C&D AT07 to AT23

AT-07, AT-09, AT-11, AT-15, AT-19, AT-23

C016-371-10

DCX Mount Kit, C&D AT-27

AT-27

C016-732-10

DCX Mount Kit, C&D AT-27P to AT-39P

AT-35P, AT-39P

C016-1017-10

DCX Mount Kit, C&D MSE1440

MSE-1440

C016-246-10

Table 13. 

Battery Mounting Bracket Kits - For GNB

® 

Batteries

DESCRIPTION

APPLICABLE BATTERY SYSTEM

PART NUMBER

DCX Mount Kit, GNB 90A5 to 13

90A05, 90A07, 90A09, 90A11, 90A13

C016-231-10

DCX Mount Kit, GNB 100A29 to 33

100A29, 100A31, 100A33

C016-225-10

DCX Mount Kit, GNB90A13

100A17, 100A19, 100A21, 100A23, 100A25, 

100A27

C016-228-10

Table 14. 

Battery Mounting Bracket Kits - For East Penn Manufacturing Batteries - Interlocking

DESCRIPTION

APPLICABLE BATTERY SYSTEM

PART NUMBER

DCX Mount Kit, Unigy 95-17 to 95-27, 

Interlocking

95-17, 95-19, 95-21, 95-23, 95-25, 95-27

C016-252-10

DCX Mount Kit, Unigy 95-29 to 95-33, 

Interlocking

95-29, 95-31, 95-33

C016-210-10

DCX Mount Kit, Unigy 125-33, Interlocking

125-33

C016-374-10

DCX Mount Kit, Unigy 6AVR125-33, 

Interlocking

6AVR125-33 NEBS; 3x8

C016-1658-10

Table 15. 

Battery Mounting Bracket Kits - For East Penn Manufacturing Batteries - Non-Interlocking

DESCRIPTION

APPLICABLE BATTERY SYSTEM

PART NUMBER

DCX Mount Kit, 95-17 to 95-27, Non-

Interlocking

95-17, 95-19, 95-21, 95-23, 95-25, 95-27

C016-250-10

DCX Mount Kit, 95-29 to 95-33, Non-

Interlocking

95-29, 95-31, 95-33

C016-214-10

Table 16.  Model Accessories

DESCRIPTION

PART NUMBER

EPO Switch, Wall Plate Assembly

C016-211-10

TRD Thermal Runaway Detector Kit

C016-934-10

Summary of Contents for C016-1001-10

Page 1: ...DCX Series Top Terminal Battery Disconnect System Installation and Operation Manual Effective January 2021...

Page 2: ...rovides fumes safety information to PREVENT INJURY OR DEATH to the technician or user WARNING FUMES HAZARD FIRE HAZARD WARNING provides flammability safety information to PREVENT INJURY OR DEATH to th...

Page 3: ...system please contact Alpha Technologies Services Inc or your nearest Alpha representative Alpha shall not be held liable for any damage or injury involving its enclosures power supplies generators b...

Page 4: ...cuit Overloading 7 4 2 5 Reliable Earthing 7 4 2 6 Disconnect Device 7 4 3 Battery Top Terminal Mount 8 4 3 1 Termination Bus Assembly 8 4 3 2 Battery Top Mounting Brackets 9 4 4 Chassis Ground 10 4 5...

Page 5: ...art numbers refer to Section 6 on Page 17 2 0 2 0 Theory of Operation Theory of Operation The DCX disconnect product family includes multiple amperage ratings and installation mounting schemes to prov...

Page 6: ...otification within 24 hours of delivery of any shipping damage in order to cover the cost of the damage via repair or replacement It is the responsibility of the recipient to inspect the shipment imme...

Page 7: ...ment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised 4 2 3 4 2 3 Mechanical Loading Mechanical Loading Mounting of the equipment in...

Page 8: ...y removing the phillips head screws as shown in Fig 3 Step 2 Remove the 3 8 in socket head cap hardware from the bottom of the circuit breaker as shown in Fig 4 Step 3 Remove the three pre installed p...

Page 9: ...ackets will require finger tight installation onto the DCX to properly allow marking for self tapping screw locations EnerSys C D GNB mounting bracket kits or for 1 4 in X 20 threaded insert locations...

Page 10: ...in lbs Step 7 After mechanical mounting of DCX unit has been completed snap the two black plastic hole plugs into the access holes that cover the 3 8 in mounting bolts see Figure 13 4 4 4 4 Chassis Gr...

Page 11: ...ch function disabled via a slide switch located on the circuit board see Figure 16 Slide this switch to the enabled position if the EPO function is desired 4 7 4 7 Alarm Contacts Alarm Contacts The DC...

Page 12: ...HAZARD MAKE SURE THAT ALL FEEDER CABLES HAVE HEAT SHRINK APPLIED PRIOR TO TERMINATION AND THAT NO OXIDE COMPOUND IS APPLIED TO ALL COPPER TO COPPER CONNECTIONS SEE SECTION 5 FOR TERMINAL SPECIFICATION...

Page 13: ...ith the plastic safety covers preinstalled These covers will require removal to allow access to the inside of the unit during cable installation It is important that all plastic covers have been reins...

Page 14: ...0A CONNECTIONS Communications Battery Positive Terminal block 14 16 AWG Output Termination 1 2 in Threaded insert 1 75 in CTC 4 positions 3 8 in Threaded insert 1 in CTC 3 positions Chassis Ground 1 4...

Page 15: ...P50 17 3X8 DDmP50 17 C016 2314 10 DCX Mount Kit EnerSys DDmP50 17 4X6 DDmP50 17 C016 2300 10 DCX Mount Kit EnerSysDDmP85 15 4x6 DDmP85 15 C016 2320 10 DCX Mount Kit EnerSys DDmP85 21 3X8 DDmP85 21 C01...

Page 16: ...00A25 100A27 C016 228 10 Table 14 Battery Mounting Bracket Kits For East Penn Manufacturing Batteries Interlocking DESCRIPTION APPLICABLE BATTERY SYSTEM PART NUMBER DCX Mount Kit Unigy 95 17 to 95 27...

Page 17: ...17 C048 699 30 R03 Rev B 01 2021 Appendix A Appendix A Mechanical Drawings Mechanical Drawings A 1 A 1 DCX Battery Disconnect Isometric View DCX Battery Disconnect Isometric View...

Page 18: ...18 C048 699 30 R03 Rev B 01 2021 A 2 A 2 DCX Battery Disconnect Dimensions DCX Battery Disconnect Dimensions...

Page 19: ...19 C048 699 30 R03 Rev B 01 2021 A 3 A 3 DCX Chassis Ground Locations DCX Chassis Ground Locations...

Page 20: ...20 C048 699 30 R03 Rev B 01 2021...

Page 21: ...21 C048 699 30 R03 Rev B 01 2021...

Page 22: ...Technical Support 1 800 863 3364 For more information visit our website at www alpha com 2021 Alpha Technologies Services Inc All Rights Reserved Trademarks and logos are the property of Alpha Techno...

Reviews: